background image

MICROSCOPE COMPONENTS    

LIGHT INTENSITY CONTROL

The intensity of the top (incident light) LEDs or bottom (transmitted light) LED can be adjust-

ed to the preferred brightness (0 through 10) by using the dimmer control located on the side 

of the base. 

ILLUMINATOR ON/OFF SWITCHES

A tri-illumination system is incorporated into the stand. The illumination system is controlled 

by top (incident light) and bottom (transmitted light) on/off switches located at the base of 

the stand. The incident illuminator is used for opaque specimens, while the transmitted 

illuminator effectively illuminates the internal structure of transparent specimens. Translucent 

specimens may be seen in greater detail if both illuminators are used simultaneously.

MAGNIFICATION KNOB 

Used to change the SILVER30 series magnification settings.

STAGE PLATE

Frosted  glass, black and white stage plates are provided with the microscope stand. The 

frosted glass stage plate allows light from the bottom illuminator to pass through. The black and 

white stage plates can be used for additional contrast to the specimen that is being viewed.

STAND 

Used to support the stereo microscope head. The height is adjustable which allows the head 

to change its focusing range. The stand also contains the top and bottom Illuminators.

TOP ANGLED ILLUMINATOR 

The top 50mW LED light source is fixed at a 45˚ angle.

TOP TURRET ILLUMINATOR

The top 6 x 60mW LED light source is fixed in a downward in a vertical position to provide 

maximum illumination of the specimen.

TURRET 

The round barrel that houses the objective lenses. The SILVER30 Series has magnifications 

that can be changed by rotating the black turret magnification knob to a different set of 

objective lenses.

SILVER30 

SERIES

 

|  04

  

SILVER

 LINE

Summary of Contents for 1100201200072

Page 1: ...SILVER30 SERIES INSTRUCTION MANUAL ENGLISH SILVER LINE ...

Page 2: ...R30B features fixed magnifications of 10X and 30X the SILVER30 S features fixed magnifications of 20X and 40X and the SILVER39Z has a variable zoom magnifica tion range of 10X 30X offering extra versatility All of them are cordless and include energy efficient variable LED illumination with three illumination systems to choose from axial incident and or transmitted one touch stage clips USB 5V out...

Page 3: ...focus at the eyepoint EYEPIECE TUBE This is the part of the head that holds the eyepieces in place Set screws in the eyepiece tubes can be used to lock the eyepieces in place STAGE CLIP Used to hold specimen in place FOCUSING CONTROL KNOB The focusing control knob located on either side of the stand are used to raise or lower the head to bring the specimen into focus The control knobs incorporate ...

Page 4: ...VER30 series magnification settings STAGE PLATE Frosted glass black and white stage plates are provided with the microscope stand The frosted glass stage plate allows light from the bottom illuminator to pass through The black and white stage plates can be used for additional contrast to the specimen that is being viewed STAND Used to support the stereo microscope head The height is adjustable whi...

Page 5: ...b 3 Look through the eyepieces and rotate the focus control knob to focus the specimen in the field of view 4 Grasp the eyepiece tubes and move them either closer together or farther apart to change the interpupillary distance to obtain a clear image Note if two separate images are observed the eyepiece tubes are too far apart and should be moved together If two overlapping images are seen the eye...

Page 6: ...ct your local authorized Motic dealer or Motic customer service BULB REPLACEMENT Unplug the stereo microscope from the electrical outlet and remove specimens from the stage before you attempt to replace an LED To prolong the life of the LED you should always turn off the unit when not in use The extra long life LED incident top illuminator bulbs can be replaced by removing the five retaining screw...

Page 7: ...be re positioned to be in the optical path Image of the specimen goes out of the focus all by itself Use the tension control collar to tighten the focusing mechanism found on the focusing spindle Focusing knobs turn with difficulty even with tension collar loosened Microscope should be disassembled cleaned and re lubricated by a qualified authorized technician IF YOU HAVE A PROBLEM YOU MAY BE ABLE...

Page 8: ...ter purchase Normal wear routine maintenance light bulbs power supplies rechargers batteries fuses cords add on accessories damage resulting from repair by unauthorized parties accident alteration shipping misuse or abuse is not covered Warranty service is provided by Motic authorized technicians Determination of warranty is at the technician s discretion Other than set forth above Motic hereby di...

Page 9: ...2882 2792 Motic Europe S L U Spain Polígon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation Ltd Motic Incorporation Limited Copyright 2002 2020 All Rights Reserved Design Change The manufacturer reserves the right to make changes in instrument design in accordance with scientific and mechanical...

Reviews: