Motic 1100201200072 Instruction Manual Download Page 3

ARM

The frame that connects the head and the base of the microscopes. It also houses the illumi-

nation switch, carrying handle, stage ring, coaxial focus controls, and the incident (top) light.

COMBI FOCUS

The coaxial focusing system combines both the coarse and fine focus into one focusing

knob located on both sides of the microscope.

DIOPTER ADJUSTMENT

Located on the left eyepiece tube of the SILVER30 Series. This adjustment is used to fine 

focus the optics to compensate for visual differences between the user’s eyes.

BOTTOM ILLUMINATOR

This is the light source mounted in the base to provide transmitted illumination.

EYEPIECE

The  upper optical element that further magnifies the primary image of the specimen and 

brings the light rays in focus at the eyepoint.

EYEPIECE TUBE

This is the part of the head that holds the eyepieces in place.  Set screws in the eyepiece 

tubes can be used to lock the eyepieces in place.

STAGE CLIP

Used to hold specimen in place. 

FOCUSING CONTROL KNOB

The focusing control knob located on either side of the stand are used to raise or lower the 

head to bring the specimen into focus. The control knobs incorporate a slip clutch system 

which prevents the head from traveling past both ends of the focusing range. When the 

focusing limit is reached, the clutch system begins to slip to prevent gear damage.

HEAD

The 360˚ rotatable component that contains all of the optical elements of the stereo micro-

scope including the eyepieces, refracting mirrors and objective lenses. The head of the 

SILVER30 series is designed to allow users to adjust the interpupillary distance of the 

eyepieces for proper viewing.

MICROSCOPE COMPONENTS

SILVER30 

SERIES

 

|  03 

  

SILVER

 LINE

Summary of Contents for 1100201200072

Page 1: ...SILVER30 SERIES INSTRUCTION MANUAL ENGLISH SILVER LINE ...

Page 2: ...R30B features fixed magnifications of 10X and 30X the SILVER30 S features fixed magnifications of 20X and 40X and the SILVER39Z has a variable zoom magnifica tion range of 10X 30X offering extra versatility All of them are cordless and include energy efficient variable LED illumination with three illumination systems to choose from axial incident and or transmitted one touch stage clips USB 5V out...

Page 3: ...focus at the eyepoint EYEPIECE TUBE This is the part of the head that holds the eyepieces in place Set screws in the eyepiece tubes can be used to lock the eyepieces in place STAGE CLIP Used to hold specimen in place FOCUSING CONTROL KNOB The focusing control knob located on either side of the stand are used to raise or lower the head to bring the specimen into focus The control knobs incorporate ...

Page 4: ...VER30 series magnification settings STAGE PLATE Frosted glass black and white stage plates are provided with the microscope stand The frosted glass stage plate allows light from the bottom illuminator to pass through The black and white stage plates can be used for additional contrast to the specimen that is being viewed STAND Used to support the stereo microscope head The height is adjustable whi...

Page 5: ...b 3 Look through the eyepieces and rotate the focus control knob to focus the specimen in the field of view 4 Grasp the eyepiece tubes and move them either closer together or farther apart to change the interpupillary distance to obtain a clear image Note if two separate images are observed the eyepiece tubes are too far apart and should be moved together If two overlapping images are seen the eye...

Page 6: ...ct your local authorized Motic dealer or Motic customer service BULB REPLACEMENT Unplug the stereo microscope from the electrical outlet and remove specimens from the stage before you attempt to replace an LED To prolong the life of the LED you should always turn off the unit when not in use The extra long life LED incident top illuminator bulbs can be replaced by removing the five retaining screw...

Page 7: ...be re positioned to be in the optical path Image of the specimen goes out of the focus all by itself Use the tension control collar to tighten the focusing mechanism found on the focusing spindle Focusing knobs turn with difficulty even with tension collar loosened Microscope should be disassembled cleaned and re lubricated by a qualified authorized technician IF YOU HAVE A PROBLEM YOU MAY BE ABLE...

Page 8: ...ter purchase Normal wear routine maintenance light bulbs power supplies rechargers batteries fuses cords add on accessories damage resulting from repair by unauthorized parties accident alteration shipping misuse or abuse is not covered Warranty service is provided by Motic authorized technicians Determination of warranty is at the technician s discretion Other than set forth above Motic hereby di...

Page 9: ...2882 2792 Motic Europe S L U Spain Polígon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation Ltd Motic Incorporation Limited Copyright 2002 2020 All Rights Reserved Design Change The manufacturer reserves the right to make changes in instrument design in accordance with scientific and mechanical...

Reviews: