Motic 1100201000026 Instruction Manual Download Page 19

Summary of Contents for 1100201000026

Page 1: ...Motic Incorporation Ltd Instructions Manual English RED30 SERIES...

Page 2: ......

Page 3: ...2 2 Part names 08 2 3 Application 09 2 4 Instrument and its technical specifications 09 3 First time use operation 10 3 1 First time use 10 3 2 Operation of the stereo microscopes 12 3 3 Modification...

Page 4: ......

Page 5: ...to the EN 61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use 1 3 Unpacking transportation storage The original shipping container a foam box in a fibe...

Page 6: ...Motic microscope repair agency to have it repaired Please be sure to turn off the power before opening the instrument to replace LED illuminator or replace the fuse Only use a fuse for the rated curr...

Page 7: ...7 2 1 General Views 2 INSTRUMENT DESCRIPTION RED39Z...

Page 8: ...1 Eyepiece 6 Base 2 Binocular tube 7 Handle 3 Objective turret 8 Focus knob 4 Sample clip holder 5 Stage plate 9 Brightness adjustment knob incident illumination 10 Brightness adjustment knob transmit...

Page 9: ...king distance 47mm 68mm Built in Rechargeable Battery N Y Y Illumination Incident and Transmitted LED illumination Optional Objectives Objectives 1X 3X 4X All of the models in the RED30 Series stereo...

Page 10: ...of the eyepieces and other optical components do not touch the lens surface Make sure the lock screws of the eyepieces are adjusted correctly The eyepieces should turn easily but should not be able to...

Page 11: ...ent LED brightness at the right hand of the base Figure 3a Control the transmitted LED brightness at the left hand of the base Figure 3b After use turn the brightness control to the minimum position a...

Page 12: ...models Observe with the right eyepiece only and rotate the focus knob until the image is in focus Observe with the left eyepiece and adjust the diopter ring on the left body tube until a focused imag...

Page 13: ...aining ring from the LED array and then unplug remove and finally replace the LED array When replacing the Incident illumination for RED39Z first remove the turret cover glass and the ring and then Sl...

Page 14: ...ents the eyepiece from falling out The diopter ring is located on the left body tube Please refer to the Section 3 2 2 of the Operation Instructions for the correct method of adjustment 4 2 Stand The...

Page 15: ...place with the spare fuse or contact your local distributor Check if the illuminator is burnt out if yes replace the illuminator or contact your local distributor Check if the supply voltage is the sa...

Page 16: ...rature Permissible relative humidity 10 40 C Below 31 C max humidity is 80 at 40 C linearly decreases to 50 Operation Permissible environment temperature Permissible relative humidity 5 40 C Below 31...

Page 17: ...cus adjustment mechanism Coarse focus adjustment Stroke 19 8mm rotation 47mm Objective RED30S RED39Z Paired 2X and 4X 1X 3X Eyepiece Field number 20mm Assembly diameter 30mm W10X 20 In the registered...

Page 18: ......

Page 19: ......

Page 20: ...ouse 311 Gloucester Road Causeway Bay Hong Kong Tel 852 2837 0888 Fax 852 2882 2792 Motic Spain S L U Spain Pol Ind Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax...