3.5.5   Power cord specification

To avoid malfunctions caused by voltage drop, the cross-section of the power cord must be large enough. The 
cross-section of the MK35 power cord is 2.0mm² (14AWG) and the maximum length is 3 meters. If the customer 
must connect an extension cord, the length and cross-section requirements of the extension cord are as follows.

3.5.6   Inrush current

3.6

   

Installation and operation of control options

3.6.1   Input voltage

It is forbidden to adjust the input voltage in an attempt to control the speed of the MK35 actuator. The battery or 
full-wave rectified DC power used must be within acceptable voltage range, otherwise the actuator will stop 
operating. If pulse width modulation (PWM) is used as the input power of MK35, it will cause malfunctions and 
cause permanent damage.

3.6.2   Determine control options

MK35 actuator is equipped with one of the control options in the table below. Please check the model number on 
the product label (section 3.1), and then refer to the model coding (section 6.2) to identify the control options of 
the actuator. Then check the corresponding sections in the table below for more details.

      

*

 

Remarks: End of stroke signal output

www.moteck.com

10

Options

S0L

SPL
SHL

J00

Control platform

Signal control

J1939 CAN Bus

Potentiometer

output

3.6.3
3.6.4
3.6.5
3.6.6

Section

Hall signal

output

EoS 

signal output

Motion status

feedback

  When the actuator starts, an inrush current of about 0.2 seconds will be  

    generated. The starting inrush current of MK35 can reach 3 times of the  

    maximum current under the rated load of the actuator.

  If a circuit board power supply is used, the specifications must be sufficient     

    to handle the inrush current. If batteries are used as the power source,  

    inrush current will not be a problem. Besides, the connectors, switches and  

    relays selected by user must also be able to withstand the inrush current.

Minimum cross section

4mm² (AWG 12)

Maximum length

4m

Summary of Contents for MK35

Page 1: ...Technical changes may be made to improve the product without notice 2022 5_V1 0 www moteck com Revision Actuator MK35...

Page 2: ...ting 6 Performance and Options 6 1 Performance data 6 2 Ordering key 3 4 5 5 5 6 9 10 18 18 20 24 25 26 __________________________________________ ___________________________ _________________________...

Page 3: ...duct The system or equipment manufacturer must have qualified electromechanical personnel to perform it and is responsible for transmitting relevant safety messages to the end user 1 3 Symbol descript...

Page 4: ...te conditions And before starting to control the action of the actuator it must be noted that the actuator and its connected mechanical moving parts are not blocked by other objects and no one enters...

Page 5: ...the actuator please check the product label to determine the actuator type If you need any help from MOTECK please provide the serial number and actuator model 3 2 Terminology 3 3 Working environment...

Page 6: ...that you can find the dimensions specification from the figures below Front connector types Solid 12 2mm Slot 12 2mm Solid 13mm Slot 13mm Rear connector types Solid 12 2mm Slot 12 2mm Solid 13mm Slot...

Page 7: ...hown in the sketch below 5 If the actuator is used on the equipment to rotate with the mounting pin as the axis it must be ensured the housing and other mechanical parts will not interfere and damage...

Page 8: ...torque required to drive the extension tube with the hand crank is about 1 4Nm 5 The distance traveled by the actuator per rotation of the hand crank is related to the gear ratio options of the actuat...

Page 9: ...ension cord can withstand the maximum operating current of the actuator It is recommended to install an emergency stop switch at a suitable location of the power supply line Do not perform wiring with...

Page 10: ...ne of the control options in the table below Please check the model number on the product label section 3 1 and then refer to the model coding section 6 2 to identify the control options of the actuat...

Page 11: ...king range the actuator will stop running After the correct voltage input is restored the operation signal must be re sent to restore control With automatic soft start function make the equipment move...

Page 12: ...by the customer The potential value of the mechanical potentiometer can be measured through the signal wires This value is only related to the stroke position Even if the power supply is interrupted...

Page 13: ...tracts 3 There are different resolutions according to the stroke length as table below Note For strokes over 950mm the SHL option is recommended Actuator extends Y W B Blue Stroke range mm 100 450 451...

Page 14: ...tion to all the functions of the S0L option section 3 6 4 the SHL option is also equipped with dual Hall effect sensors Wiring The Hall feedback is a relative positioning And each MK35 actuator has be...

Page 15: ...lack Red Black White Resolution High 10 8V 0 6V Low GND Hall signal data Resolution pulse mm 1 7598 2 9547 3 9035 6 2580 Output GND Normally close circuit Output Vcc End of Stroke open circuit The str...

Page 16: ...r supply of the CAN Bus system if this power supply exists All command and feedback message of the J00 option including protection message are processed through CAN messages transmitted by the signal...

Page 17: ...e definitions Connect Red to positive Connect Black to negative Do not swap the polarity Input voltage 12 24V 20 Connect Black to positive same as V to extend Vin 5 32V Connect Red to positive same as...

Page 18: ...ta Link Layer Proprietary A Proprietary B Address Claimed Cannot Claim Commanded Address 61184 0x00EF00 65280 0x01EF00 60928 0x00EE00 65240 0x00FED8 Identity number Manufacture code Function instance...

Page 19: ...ators will be used in a CAN Bus network in order to save initialization time MK35 has a DIP switch for address selection Up to 16 MK35 actuators can be connected and preset addresses Before connecting...

Page 20: ...S can be the default address 16 of MK35 or the hardware address 17 31 set by the user Section 4 2 2 Or it can be set to FF 255 as the broadcast mode Source address SA The unique address of the J1939 c...

Page 21: ...8 Bits Reserved Not used suggest 0 1 5 4 0 Stop actuator moving 1 Extend the actuator 2 Retract the actuator 3 Move to designated position Move 1 1 2 Clear error code 0 Do not clear error code 1 Clear...

Page 22: ...ers as following definition 3 Data field definition EDP 0 DP 0 PF 255 PS address 8 bits Action 16 bits Position 8 bits Current 8 bits Run speed or Set ramp 8 bits Error codes 3 bits Priority 1 bit EDP...

Page 23: ...urrent Default 0 When it is detected that the current of actuator exceeds the set limit for 300ms the protection is activated to stop the actuator The error flag turns on value 1 6 1 1 Voltage error D...

Page 24: ...sure the power supply can provide enough current to drive the rated load 1 No 2 3 The actuator does not move and makes no sound The actuator is not getting the correct input voltage range Make sure to...

Page 25: ...25 25 15 10 000 2 600 4 500 6 800 No load 11 40 24 18 Full load 29 17 13 8 No load Full load 1 5 1 5 1 5 1 5 24V 12V 3 0 3 0 3 0 3 0 9 9 10 9 24V 12V 18 18 20 18 Duty Cycle Push Pull Max N 10 1 20 1...

Page 26: ...rear connectors shown in standard 0 Reserved 0 Reserved Reserved 0 Reserved Cable length 0 500mm 1 1500mm 3 3000mm XXXX 0100 1000mm one step in every 50mm Motor code G 4500rpm Control options S0L Sign...

Reviews: