TIG Inverter PONTIG 3200 DC MOST
-13-
User manual
Version 1.1 of 22.01.2018 EN
11
Function facilitating MMA electrode strike. The value set from
75% to 200% of the welding current A1, duration from 0.0 to
10.0 seconds.
9
Current rising time (only for TIG) Time when current rises
from Istart to A1, setable from 0.0 to 10 seconds
12
Welding current and T1 welding current time (main welding
current in Amper, other parameters are set in proportion
thereto, set in a range from 5 to 320 A)
12
A1 welding current time only for TIG puls, set in a range from
0 to 10 seconds
13
Basic current A2 expressed in % on the A1 value in a range
5% - 100%
13
Basic current and T2 base current time
•
For TIG without pulse: the base current value
activated with an additional TIG torch button
•
For TIG pulse: set in percentage relation to the A1
welding current in a range from 5% to 100%
13
A1 base current time (only for TIG pulsating current, set in a
range from 0 to 10.0 seconds)
12+13
Hz
TIG pulse, high frequency welding current frequency ranges
from 10 to 500 Hz
14
ArcForce function, arc strengthening at MMA welding, useful
especially when welding pipes, expressed in % from the A1
value. Regulation range from 100% to 200%
15
Current drop time (only for TIG 2-tact: time when current
drops from A1 value to 0A value. For TIG 4-tact means drops
from A1 current to the Istop value. Set time from 0.0 to 10
seconds).
16
Failure signalling diode
17
End current (only for TIG 4-tact: welding current which lasts
as long as the torch button is pressed). Regulation range
from 5% to 100%
18
Gas postflow time (only for TIG: time when gas flows out after
the completion of welding, set from 0.0 to 10.0 seconds).
Factory value 2.5 s
6
Diode lights with the VRD function active, at MMA electrode
welding
23
Display
Table 3: Units for particular functions
19
A
Welding current
20
%
Percentage share of welding current
21
Hz
Frequency