2. Maintenance (power supply and wire feeder)

ATTENTION:

 In order to carry out any repair or maintenance activity, it is recommended to 

contact your nearest technical support of 

RYWAL-RHC

 (a list of authorized service shops is 

available on the last page of the manual).

In the event of noticing any damage, the welder should stop working, disconnect the device 

from power supply and report it to direct supervisor or appropriate service - 

RYWAL-RHC

 

technical support.

General maintenance (daily)

- check the condition of cables and connections, replace if necessary,

- remove spatter from the gas nozzle of the welding torch, spatter may transfer with the shiel-

ding gas to the welding arc, tend to disrupt the shielding gas flow and can effect in a short 

circuit,

- check condition of welding torch, replace if necessary,

- check condition and operation of the cooling fan; keep the cooling air inlet and outlet openings

- keep it clean at all times.

Periodic maintenance (every 3 months at least)

Periodic maintenance frequency can be increased depending on the environment conditions

in which the device is operating. Maintenance scope:

- using a stream of dry air (at low pressure) remove the dust from the outer parts of the casing 

and from inside of the welding device,

- check and tighten all the screws,

- check the state of all electrical contacts and correct if necessary.

 

 

ATTENTION:

 Power supply must be disconnected from the device before any 

 

maintenance and service work. After each repair, perform a proper check to ensure  

 

safe use.

Mandatory device checks

According to the Labour Code provisions: „All responsibility for the safe use of machinery

and equipment shall be borne by the owner.”

This results in the obligation to perform periodic and post-repair checks and inspections of 

equipment.

Periodic tests are carried out at least once a year (legal basis EN ISO 17662 clause 4.2), and 

post-repair tests after each repair that restored welding functionality (legal basis: EN 60974-4 

clause 4.6).

All above services are performed by the technical support of 

RYWAL-RHC

.

In accordance with Regulation 2019/1784 (EU) Annex II pt. 2. b1, 

The RYWAL-RHC company provides information on repairs and maintenance to 

PROFESSIONAL TECHNICAL SUPPORT PROVIDERS under the terms of the regulation.

Summary of Contents for FANMIG 280-4N Minor

Page 1: ...4N Minor 51 000 22334 Attention Before starting work every person using or responsible for maintenance work on this device should familiarize with the entire content of these User s Manual This will...

Page 2: ...without proper eye protection Pay attention to providing safety for bystanders against welding radiation Use ventilation and filters in order to remove welding fumes from the work site Use individual...

Page 3: ...s intended for use in workshop and industrial conditions The device application nearby to residential buildings espe cially the power supply using a home electrical network may interfere with the oper...

Page 4: ...ll colour absorption of UV radiation FIRE PROTECTION Welding work station should be located at a safe distance from flammable materials placed especially on the floor or walls All flammable materials...

Page 5: ...nance frequency can be increased depending on the environment conditions in which the device is operating Maintenance scope using a stream of dry air at low pressure remove the dust from the outer par...

Page 6: ...step setup setting FANMIG 280 4N 10 steps FANMIG 320 4N 12 steps Transformer and the induction coil are made of copper insulation class F and are fan cooled The device is sensor protected against ove...

Page 7: ...290 A 28 5 V 210 A 24 5 V 170 A 22 5 V 340 A 31 V 230 A 25 5 V 200 A 24 V Welding current set point number 10 12 Wire feeder 4 roll 2N 4N 4 roll Wire feeding speed mm 1 19 1 19 Welding torch cooling...

Page 8: ...on 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 8 5 FANMIG 280 4N 320 4N Minor control panel Figure 1 Device front panel V1 main switch V3 welding current accurate switch P1 Minor version contro...

Page 9: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 9 5 1 Minor version control panel 5 4 3 2 1 6 7 8 9 10 11 12 Figure 2 Control panel P1 as on Fig 1 on Minor version...

Page 10: ...ng secondary parameters see button description 6 press simultaneously with the button 3 6 Display shows secondary parameters Wire feeding speed adjustable PrG gas pre flow s PoG gas post flow s brn wi...

Page 11: ...2 Return to factory settings RESET 5 3 Setting range of the individual welding functions Symbol on Display 6 Parameter MIN MAX Unit SPo Welding time for spot weld and interm welding 0 5 20 s Int Paus...

Page 12: ...rm TR 404 6 5635 Tuleja 10 Shaft 10 7 5630 Podk adka mocuj ca RA 5 Retaining ring for shaft RA5 8 5636 Tuleja 6 Shaft 6 9 5637 Spr yna g rna TR 404 Spring TR 404 10 5638 Korpus dociskowy TR 404 Fixing...

Page 13: ...1 0 1 2 22 30 TD tube wire 5113007899 Rolka 1 2 1 4 22 30 TD Roll 1 2 1 4 22 30 TD tube wire 24 25 26 5647 Ko o z bate dolne komplet TR 404 Gear wheel upper TR 404 set 27 5649 Tuleja TR 404 Shaft TR...

Page 14: ...ng cutting it off with off cuts and guide it onto feeding roll with upper press mechanism is lifted Than guide the wire through eu ro socket and welding torch Press the pressure arm after inserting th...

Page 15: ...Buttons 10 and 11 LED blinks 4 cycle spot welding In order to set the spot or intermittent welding press and hold button 3 for longer than 2 se conds A choice between 2 and 4 cycle when constant weldi...

Page 16: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 16 9 Spare parts Figure 4 FANMIG 280 4N Minor spare parts...

Page 17: ...1 0 1 2 1 28 V9040040 Mocowanie kabla S12 Cable clamp S12 1 29 AO 20610 Szybkoz czka e ska 35 70 panel Quick Connector 35 70 Panel Socket 2 30 VS040258 a cuch na butl 70 cm Chain 70 cm 2 31 VM0203 1...

Page 18: ...Panel przedni ALF 280 320 compact Synergy neutral Front panel Alf 280 320 compact Synergy neutral 1 62 V0005 Podwozie Alf 400 Carriage unit Alf 400 1 63 V0004 Podp rka Alf 400 Support Alf 400 1 64 V00...

Page 19: ...1 0 1 2 1 28 V9040040 Mocowanie kabla S12 Cable clamp S12 1 29 AO 20610 Szybkoz czka e ska 35 70 panel Quick Connector 35 70 Panel Socket 2 30 VS040258 a cuch na butl 70 cm Chain 70 cm 2 31 VM0203 1...

Page 20: ...r Alf 400 1 61 V0029 Panel przedni ALF 280 320 compact Synergy neutral Front panel Alf 280 320 compact Synergy neutral 1 62 V0005 Podwozie Alf 400 Carriage unit Alf 400 1 63 V0004 Podp rka Alf 400 Sup...

Page 21: ...eed speed Reduce speed Too high welding current Reduce the welding current Welded material too dirty Clean the welded material CO2 as shielding gas Changing the shielding gas to mix gas type M21 Wire...

Page 22: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 22 11 Electrical scheme Figure 6 FANMIG 280 4N device electrical diagram...

Page 23: ...trical and Electronic Equipment after decommissioning the device must be recycled by a specialized company Do not dispose of worn out welding equipment with domestic waste The components used to build...

Page 24: ...320 4N Minor Semi Automatic Welding Machine 5 The subject matter of this declaration referred to above is in line with the relevant requirements of EU harmonization legislation Low Voltage Directive L...

Page 25: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 25 NOTATKI...

Page 26: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 26 NOTATKI...

Page 27: ...User Manual Version 1 0 of 22 04 2021 FANMIG 280 4N Minor 320 4N Minor 27 NOTATKI...

Page 28: ...oc aw ul Stargardzka 9 C tel 71 351 79 34 71 351 79 36 65 410 Zielona G ra ul Fabryczna 14 tel 695 596 535 667 671 697 603 760 405 ROM NIA RYWAL RHC Romania SRL Bra ov Str Calea F g ra ului nr 59 Stan...

Reviews: