User Manual
Version 1.0 of 22.04.2021
FANMIG 280-4N Minor
320-4N Minor
-10-
1
Button
•
Wire installation (of a new spool)
•
Deleting/Resetting parameters (simultaneously press button 2)
2
Button
•
Gas test
•
Deleting/Resetting parameters (simultaneously press button 1)
3
Button
•
Switch between 2-step and 4-step
•
Pressing longer than for 2 s switches on spot welding (led 11 lights up) or intermittent
•
(led 11 blinks)
•
Entering secondary parameters - see table 3 (press simultaneously with the button 5)
4
LED
2-step
5
Button
•
Entering secondary parameters - see button description 6 (press simultaneously with the
button 3)
6
Display shows secondary parameters
•
Wire feeding speed (adjustable)
•
PrG – gas pre-flow [s]
•
PoG – gas post-flow [s]
•
brn – wire burn time [s]
•
SPo – spot-welding time [s] (active spot-welding only)
•
Int - break time at intermittent welding [s] (active spot-welding only)
7
LED
cooling system fault (optional)
8
LED
overheat Let the device to cool down using a fan
9
Display shows secondary parameters
10 LED 4-cycle
11 LED
•
Switches on – spot welding
•
Blinks – intermittent welding
12 Knob
•
Sete the feed speed
•
Selects secondary parameters
Table 2: Minor control panel function markings
Attention!