Section 4: Operation
4-17
Moseley SL9003Q
602-12016-01 Revision J
To determine the rate at which errors occur or how many errors occur in any period of time,
multiply the BER by the Data Rate and scale by the amount of time. For instance to
calculate the average number of errors in an hour period: BER (errors/bit)* Data Rate
(bits/sec) * 60 secs/min * 60 min/hour. For example:
1.46E-10 errs/bit * 2.048E+06 bps * 60 secs/min * 60 min/hour = 1.08 errors/hour
4.4.12.3 QAM Demodulator Status - Receiver Screens (Continued)
Function Settings
Summary
SLOSS
x.xxxE+xx Signal
Loss
ES
x.xxxE+xx Error
Seconds
SES
x.xxxE+xx
Severely Errored Seconds
UNAS
x.xxxE+xx Unavailable
Seconds
Used for Evaluating and
troubleshooting errors over
time. Press ENTER to clear the
screen.
BAUD
LOCK (default)
UNLOCK
Indicates modulator PLL is locked to incoming data clock
FEC
LOCK (default)
UNLOCK
Indicates FEC decoder is synchronized
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...