A-6
Appendix A: Path Evaluation Information
Moseley SL9003Q
602-12016-01 Revision J
Line 8
: Enter the total connector losses. A nominal figure of -0.5 dB is reasonable (based
on 0.125 dB/mated pair).
Line 9
: Enter all other miscellaneous losses here. Such losses might include power dividers,
duplexers, diplexers, isolators, isocouplers, and the like. Losses are 1.5 dB per terminal.
These only apply for full duplex systems.
Table A-4. Branching Losses
System Type
TX Loss
RX Loss
Total Loss
Non-Standby Full Duplex Terminal (400 MHz)
1.2 1.2 2.4
Hot Standby Full Duplex Terminal (400 MHz)
1.2 4.2 5.4
Non-Standby Full Duplex Terminal (900 MHz)
1.5 1.5 3.0
Hot Standby Full Duplex Terminal (900 MHz)
1.5 4.5 6.0
Line 10
: Enter obstruction losses due to knife-edge obstructions, etc.
Line 11
: Total lines 5 to 10 and enter here. This is the total loss in the proposed system.
Line 12
: Enter the total gain from line 4.
Line 13
: Enter the total loss from line 11.
Line 14
: Subtract line 13 from line 12. This is the unfaded signal level to be expected at
the receiver. (Convert from dBm to microvolts here for reference).
Line 15
: Enter the minimum signal required for 1x10E-4 BER using the information in Table
A-5.
Table A-5. Typical Received Signal Strength required for BER of 1x10E-4*
Data Rate Configuration
High Sensitivity 16 QAM
High Efficiency 64 QAM
2 Chnl, 1024 kbps
-93 dBm
-89 dBm
2 Chnl, 1536 kbps
-91.5 dBm
-87.5 dBm
4 Chnl, 1536 kbps
-91.5 dBm
-87.5 dBm
4 Chnl, 2048 kbps
-90 dBm
-86 dBm
* Excludes all branching losses
Line 16
: Subtract line 15 from line 14 and enter here. This is the amount of fade margin in
the system.
Line 17
: Enter the Terrain Factor.
a (terrain factor)
= 4 for smooth terrain.
= 1 for average terrain.
= 1/4 for mountainous, very rough, or very dry terrain.
Line 18
: Enter the Climate Factor.
b (climate factor)
= 1/2 for Gulf coast or similar hot, humid areas.
= 1/4 for normal interior temperate or northern regions.
= 1/8 for mountainous or very dry areas.
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...