Installation
2-2
602-95555-01 Rev A
NXE1-20 Digital Radio
PRE-INSTALLATION NOTES
Always pre-test the system on the bench in its intended configuration prior to installation at a
remote site. Avoid cable interconnection length in excess of 1 meter in strong RF environments.
We highly recommend installation of lightning protectors to prevent line surges from damaging
expensive components.
2.3 Rack Mount
The product is normally rack-mounted in a standard 19” cabinet. Leave space clear above (or
below) the unit for proper air ventilation of the card cage. The rack ears are typically mounted as
shown in Figure 2-1. Other mounting methods are possible by changing the orientation of the
rack ears.
Figure 2-1.NXE1-20 Typical Rack Mount Bracket Installation
2.4 Duplexer: Internal/External
Various duplexers, both internal and external, can be utilized. For current duplexers utilized with
the radios, please see the Appendix.
2.5 Rear Panel Connections & Indicators
Please refer to the Figure 2-2 for a pictorial of a typical product rear panel (internal duplexer).
Following is a descriptive text of the connections and LED indicators.