Front Panel Operation
3-26
602-95555-01 Rev A
NXE1-20 Digital Radio
QAM Modem Configure (continued)
QAM Interface
Intfc
DTE Trnk
TX CLOCK
Clk Src
Recov
Clk Ph
Norm
TX Clk Out
Clk Ph
Norm
RX Out
Data Src
Norm
Clk Src
Norm
Clk Ph
Norm
Qmdm
FVERS
1.5
XVER
2.1
Function
Settings
Summarys
Interface
Trunk
Radio (bkpln)
Uses Trunk for I/O.
Uses Backplane for I/O.
Clk Src (Tx
Clock)
Internal, EXT TXC,
EXT RXC,
Recovered
Clock source of the Transmitter.
Clk Ph (Tx
Clock)
Inverted, Normal
Clock Phase of the Transmitter.
Clk Ph (Tx
Clock Out)
Inverted, Normal
Clock Phase of the Transmitter Clock Out.
Data Src (Rx
Out)
Norm, RPT, Loop
Data Source of the Receiver Out. Normal means the
source is either BKPLN or TRNK; RPT sets the radio to
Repeater; Loop sets the radio to loopback mode.
Clk Src (Rx
Out)
Internal, EXT TXC,
EXT RXC, Recov
Clock Source of the Receiver Out.
Clk Ph (Rx Out)
Norm, Inverted
Clock Phase of the Receiver Out.
Fvers
Xvers
Internal is the internal clock of the NXE1-20; EXT TXC is the External Transmit Clock; EXT
RXC is the External Receive Clock; Recovered is the recovered clock from the receiving RF.
NOTE: See the User Clock Options Conceptual Diagram in Figure 3 -4 below for clarification.
3.4.19.1
Typical Configuration
A typical installation of NXE1-20 Digital Radios involves configuring each NXE1-20 as either Data
Communications Equipment (DCE) or as Data Terminal Equipment (DCE), as illustrated below: