OPERATION
Page 18 of 23
!
!
CAUTION: AVOID INHALING FUMES EMITTED FROM THE HEATER’S FIRST USE.
SMOKE AND ODOR FROM THE BURNING OF OILS USED IN MANUFACTURING WILL
APPEAR. BOTH SMOKE AND ODOR WILL DISSIPATE AFTER APPROXIMATELY 30
MINUTES. THE HEATER SHOULD NOT PRODUCE THICK BLACK SMOKE.
NOTE:
The burner may be noisy when initially turned on. To eliminate
excessive noise from the burner, turn the Control Knbo to the
“LOW” position. Then, turn the knob to the level of heat desired.
When heater is ON:
Emitter screen will become bright red due to intense heat. The
color is more visible at night. Burner will display tongues of blue
flame. These flames should not be yellow or produce thick black
smoke, indicating an obstruction of airflow through the burners.
Operation pressure checked:
If the flame is very small, this is because the supply pressure is
not enough. Please refill gas cylinder.
Re-light:
1) Turn the control knob to “OFF” position.
2) Wait five (5) minutes before attempting to relight burner.
3) Repeat steps beginning with step 2 of the lighting instruction
above.
Shut down instructions:
1) Push in and turn control knob clockwise to “OFF” position.
2) Turn LP cylinder gas valve clockwise to “OFF” position when
heater is not in use.
NOTE:
After use, some discoloration of the emitter screen is
normal.
The Event of Gas Leakage:
1) Turn the control knob to “OFF” position.
2) Turn LP cylinder valve to “OFF” position.
3) Wait 5 minutes to allow gas to dissipate.
4) If odor continues, immediately call gas supplier or fire
department.
WARNING:
Heater will be hot after use.
Handle with extreme care.