SAFETY CHECK
WARNING: ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS
Page 15 of 23
!
PRODUCT. PROPER ASSEMBLY IS THE RESPONSIBILITY OF THE INSTALLER.
Annual check operation:
a. Remove the observation window panel by
un-screwing two bolts.
b. Turn on LP gas cylinder valve.
c. Spoon several drops (or use squirt bottle)
of the solution onto gas hose connection
and automatic valve connection and the
injector connection.
d. Inspect the connections and look for
bubbles.
e. If no bubbles appear, the connection is
safe.
f. If bubbles appear, there is a leak. Shut off
the LP gas cylinder valve, loosen and then
re-tighten this connection.
g. Check again for leaks.
h. If bubbles still appear, close the LP gas
cylinder vavle and call our customer
service line 1-866-814-0585 or 1-888-
922-2336.
i. Hose checking steps:
(1) Unscrew M6 x 14 bolts from the pole.
(2) Pull out the head assembly hose and
regulator from the pole.
(3) Check if there are cracks or worn
sections on the hose. If yes, replace the
hose and regulator immediately.
(4) Check for leaks according to the above
steps after replacing the hose and
regulator.