Mosa GE 7000 KDes-gs Use And Maintenance Manual Download Page 13

INSTALLATION AND ADVICE

M

2.6

REV.1-06/07

INSTALLATION AND ADVICE BEFORE USE

GASOLINE ENGINES

+

 

Use in open space, air swept or vent exhaust gases, 

which contain the deathly carbone oxyde, far from 

the work area.

DIESEL  ENGINES

+

 

Use in open space, air swept or vent exhaust gases 

far from the work area.

POSITION

Place the machine on a level surface at a distance of at 

least 1,5 m from buildings or other plants.

Check that the air gets changed completely and the hot 

air sent out does not come back inside the set so as to 

cause a dangerous increase of the temperature.

+

 

Make sure that the machine does not move during the 

work: 

block

 it possibly with tools and/or devices made 

to this purpose.

Maximum leaning of the machine (in case of dislevel)

10°

10°

= 20° max

10°

10°

= 20° max

26/1

1/99  M2-6GB

1,5

m

1,5

m

1,5

m

GAS

DI

SCARICO

EXHAUST OUTPUT

MOVES OF THE MACHINE 

 

+

 At any move check that the engine is 

off

, that there are 

no connections with cables which impede the moves.

PLACE OF THE MACHINE

ATTENTION

For a safer use from the operator 

DO NOT

 

fit  the  machine  in  locations  with  high  risk 

of flood.

Please do not use the machine in weather 

conditions which are beyond IP protection 

shown both in the data plate and on page 

named "technical data" in this same manual.

 

!

Summary of Contents for GE 7000 KDes-gs

Page 1: ...USE AND MAINTENANCE MANUAL M A D E I N I T A L Y GE 7500 HBSL AVR GE 7500 HBSLE AVR Codice Code Codigo Kodezahl 257759003 Edizione Edition Edici n Ausgabe 05 2014...

Page 2: ......

Page 3: ...rovided elastic support which must damp the vibrations and also eliminate sounds which would produce noise The unit has a protective closed frame which protects it against unintentional impacts during...

Page 4: ...continue to satisfy the needs of its clients aswell as to improve the transparency and thecom munications regarding all the company s activesin accordance with the official procedures and inhar mony w...

Page 5: ...2 7 INSTALLATION AND DIMENSIONS M 3 UNPACKING M 4 1 TRANSPORT AND DISPLACEMENTS M 6 ASSEMBLY CTM TR M 25 SET UP FOR OPERATION M 26 STARTING AND STOPPING M 31 CONTROLS M 37 USE AS A GENERATOR M 43 MAI...

Page 6: ...matter In no case MOSA division of B C S S p A will be held responsible for any damaga direct or indirect in relation with the use of the given information MOSA division of B C S S p A does not take...

Page 7: ...ke parts away do not tear pages and keep it in places protected from dampness and heat You must take into account that some figures contained in it want only to identify the described parts and theref...

Page 8: ...cluded in any machine standard equipment Here below the adopted symbol CE marking is clearly readable and unerasable and it can be either part of the data plate Furthermore on each model it is shown t...

Page 9: ...Marchio Brand Modello Model Matricola Serial number conforme con quanto previsto dalle Direttive Comunitarie e relative modifiche est en conformit avec ce qui est pr vu par les Directives Communautair...

Page 10: ...urs limited at 500 h No overload is admitted Prime power PRP maximum available power for use at variable loads for a yearly illimited number of hours The average power to be taken during a period of 2...

Page 11: ...r whatever event which may cause serious injuries or death predispose the first aid in accordance with the ruling labour accident standards or of local instructions FIRE PREVENTION In case the working...

Page 12: ...ersons Use only with safety clothing It is compulsory to use the personal protection means given in equip ment Use only with safety clothing It is compulsory to use the personal protection means given...

Page 13: ...a dangerous increase of the temperature Make sure that the machine does not move during the work block it possibly with tools and or devices made to this purpose Maximum leaning of the machine in cas...

Page 14: ...GE 7000 HBSL HBSLE AVR GE 7500 HBSL HBSLE AVR M 2 7 REV 0 05 14 Installazione Installation Installation I GB F Luftzirkulation Instalaci n...

Page 15: ...Dimensioni Dimensions Dimensions I GB F Abmessungen Dimensiones GE 7000 HBSL HBSLE AVR GE 7500 HBSL HBSLE AVR M 2 7 1 REV 0 05 14 STANDARD STD CTM7 1 STD CTM7 2...

Page 16: ...rough handling or taking away of parts contained inside the packing or in the set In case you find damages rough handling or absence of parts envelopes manuals etc we advise you to inform immediately...

Page 17: ...th it s packaging and conform to local rules and regulations Only authorized persons involved in the transport of the machine should be in the area of movement DO NOT LOAD OTHER PARTS WHICH CAN MODIFY...

Page 18: ...Lift the machine and assemble the parts as shown in the drawing ATTENTION The CTM accessory cannot be removed from the machine and used separately actioned manually or following vehicles for the tran...

Page 19: ...correctly installed and that there are no leaks around the filter which couldlead to infiltrationsof non filteredair to the inside ofthe motor Gasoline is highly fammable Refuel with motor shut off in...

Page 20: ...slowly RUNNING IN During the first 50 hours of operation do not use more than 60 of the maximum output power of the unit and check the oil level frequently CAUTION CLOSED OPEN CHOKE ROD 7 pull the rop...

Page 21: ...encieux d chappement Silenciador de descarga 28 Interruttore motore Engine switch lnterrupteur moteur Interruptor motor 31 Tappo scarico olio motore Oil drain tap Bouchon d charge huile moteur Tap n v...

Page 22: ...nditions and nominal values for voltage frequency power factors cos There are various types of power PRIME POWER PRP STAND BY POWER established by ISO 8528 1 and 3046 1 Norms and their definitions are...

Page 23: ...o the motor allows it see to a start up with reduced voltage star point triangle start up or with autotransformer or use a soft start system In all cases when the user circuit requires the start up of...

Page 24: ...protection forcefully pressed to prevent its intervention ATTENTION USAGE WITH EAS AUTOMATIC START UP PANEL The electricity generating group in combination with the EAS automatic start up panel forms...

Page 25: ...O NOT USE COMPRESSED AIR DECALS AND LABELS All warning and decals should be checked once a year and replaced if missing or unreadable STRENUOUS OPERATING CONDITIONS Under extreme operating conditions...

Page 26: ...d replace them when the maintenance requiring their removal is complete Please wear the appropriate clothing and make use of the PPE Personal Protective Equipment according to the type of intervention...

Page 27: ...n the covers and all the other parts of the machine carefully Protect the machine with a plastic hood and store it in o dry place DIESEL ENGINE For short periods of time it is advisable about every 10...

Page 28: ...he various components of the machine must be made accordingly to rules in force of law a o local rules Particular attention must be paid when getting rid of lubricating oils battery electrolyte and in...

Page 29: ...4 Polarity inverter switch Z4 Transformer 230 48V W4 Diode bridge polarity change X4 Base current diode bridge Y4 PCB control unit polarity inverter A5 Base current switch B5 Auxiliary push button ON...

Page 30: ...25460 II LEGENDA LEGEND LEGENDE REFERENZLISTE S2 Trasmettitore livello olio Oil level transmitter Tran smetteur niveau huile lstandssensor F3 Interruttore motore Engine switch Contacteur d arret moteu...

Page 31: ...Schema elettrico Electric diagram Schemas electriques GE 7000 7500 HBSLE AVR M 61 2 REV 0 05 14 Stromlaufplan Esquema el ctrico...

Page 32: ...Schema elettrico Electric diagram Schemas electriques GE 7500 HBSL HBSLE AVR M 61 3 REV 0 05 14 Stromlaufplan Esquema el ctrico...

Page 33: ......

Page 34: ...MOSA div della BCS S p A Stabilimento di Viale Europa 59 20090 Cusago MI Italia Tel 39 0290352 1 Fax 39 0290390466 WWW MOSA IT...