GE 12000 SXC/GS
GE 14000 SXC/GS
© MOSA
1.0-10/05
M
21
Start-up
11/10/05 35921-GB
check before each start-up
START-UP FROM FRONT PANEL
1
. Position the LOCAL START / REMOTE START
(I6) selector on LOCAL START
(only EAS
version)
;
2
. check to ensure the emergency stop button is
unblocked (where it is assembled);
3
. make sure the load plugs are disconnected or
the thermal-magnetic switch (Z2)
is not inserted (intervention/
insertion lever facing down), so as
to ensure the motor's start-up
without any loads inserted;
7
. Once the engine has started leave it running at a
reduced speed for some minutes.
8
. Accelerate the engine at max., set lever on
maximum position and then take up load.
4
. Make sure that the accelerator lever or the switch
(16) is at its minimum setting;
5
. lnsert the electric protection device (D-Z2-N2)
lever towards above and, where mounted, check
the isolation monitor (A3) see page M37 –
6
. Introduce the key (Q1), turn it clockwise
completely, leaving it as soon as the engine
starts and/or the push button (32) (models
without key) leaving it as soon as the
engine starts.
☞
NB.: for safety reason the key
must be kept by qualified personel.
☞
In case of unsuccessful start-up, do not
insist for longer than 5 seconds. Wait 10 -
15 seconds before attempting another start-
up .
REMOTE START
(Only EAS version)
The unit can also be started by means of the remo-
te TCM control device, or through the EAS
automatic intervention panel.
1
. Position the LOCAL START / REMOTE START
(I6) selector on REMOTE START;
2.
check that the emergency stop button is
unblocked (where it is assembled);
3
. Connect to the EAS (B3) connector the TCM or
the EAS panel.
4. Start-up with EAS
The EAS panel automatically sees to controlling
the motor’s start-up cycle.
☞
The preheating time on the EAS panel is normally
set at 10 seconds; for low temperatures, it may
be necessary to increase it to 15 or 20 seconds
to ensure start-up.
Contact an authorized Service Centre or our
Technical Service Department directly to modify
this setting.
5. Start-up with TCM
Perform the same procedure for start-up from
the front panel using the TCM start-up key (Q1).
OFF
ON
START
Time
5 min.
2 min.
1 min.
20 sec.
Temperature
≤
- 20° C
to - 20° C from -10°C
to
- 10° C from -5°C
≥
5° C
RUNNING-IN
During the first 50 hours of operation, do not use more
than 60% of the maximum output power of the unit and
check the oil level frequently, in any case please stick
to the rules given in the engine use manual.
CAUTION
!