14/10/10 25940-GB
Technical data and machine description
GE
1
0000 LD/GS
GE
1
2000 LD/GS
M
1.5
REV.0-10/10
Technical Data
GE 10000 LD/GS
GE 12000 LD/GS
GENERATOR
*
Stand-by three-phase power
-
12 kVA (9.6 kW) / 400 V / 17.3 A
*
PRP three-phase power
-
11 kVA (8.8 kW) / 400 V / 15.9 A
*Stand-by single-phase power
10 kVA (9 kW) / 230 V / 43.5 A
-
*
PRP single-phase power
9 kVA (8.1 kW) / 230 V / 39.1 A
6 kVA / 230 V / 26 A
Frequecy
50 Hz
50 Hz
Cos
ϕ
0.9
0.8
* Output powers according to ISO 8528-1
ALTERNATOR
Self-excited, self-regulated, brushless
Self-excited, self-regulated
Type
synchronous, single-phase
synchronous, three-phase
Insulation class
H
H
MOTOR
Make / Model
Lombardini / 25 LD 425/2
Type / Cooling system
Diesel 4-Stroke / air
Cylinder / Displacement
2 / 851 cm
3
*
Stand-by net power
11.5 kW (15.6 HP)
*
PRP net power
10.5 kW (14.3 HP)
Speed
3000 rpm
Fuel consumption (75% of PRP)
2.2 l/h
Engine oil capacity
1.8 l
Starter
Electric
* Output powers according to ISO 3046-1
GENERAL SPECIFICATION
Fuel tank capacity
18 l
Running time (75% of PRP)
8.2 h
Protection
IP 23
*
Dimensions on base Lxwxh
935x580x645
*
Weight on base
159 Kg
156 Kg
Acoustic power LwA (pressure LpA)
99 dB(A) (74 dB(A) @ 7 m)
99 dB(A) (74 dB(A) @ 7 m)
* Dimensions and weight without trolley/trailer.
2000 / 14 / CE
OUTPUT
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(L
WA
)
- Measure Unit dB(A):
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A):
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(
L
WA
)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
Summary of Contents for GE 10000 LD/GS
Page 21: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Page 49: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Page 77: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Page 105: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Page 112: ......
Page 133: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...