TECHNICAL DATA
21/09/07 78510-EN
C.C. WELDING
Welding current
500A/35% - 450A/60% - 400A/100%
Starting voltage
62V
(DSP 500 PS) -
65V
(DSP 500 PS-60Hz)
C.V. WELDING
Welding current
450A/60% - 400A/100%
Welding voltage
16 - 40V
WELDING CURRENT [A]
0
100
150
300
400
500
AUXILIARY POWER 3-PHASE [kW]
16
14
12
6
3
0
STATIC CHARACTERISTIC
SIMULTANEOUS UTILIZATION FACTORS
In case
Welding
and
Generation
can be used simultaneously, however, the engine
cannot
be overloaded.
The table below gives the maximum limits to be respected:
50Hz
60Hz