background image

MORTEX

 

PRODUCTS

 

INC

 

FORT

 

WORTH,

 

TX

 

76106

 

Page

 

15

 

SPD

 

TAP

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

LO

1225

1174

1121

1077

1036

976

924

877

740

629

MED

LO

1429

1386

1345

1308

1245

1220

1158

1115

1070

608

MEDIUM

1569

1529

1476

1438

1403

1368

1313

1260

1109

707

MED

HI

1785

1740

1711

1664

1619

1592

1488

1359

1137

967

HI

2129

2057

2017

1959

1838

1733

1603

1432

1225

1183

CFM

 

with

 

Coil

 

LO

1104

1059

1012

975

930

876

780

719

662

581

98

8W7W

OP

 

MED

LO

1292

1244

1214

1184

1136

1098

1053

981

773

584

a nd

 

Cabinet

 

MEDIUM

1400

1365

1334

1301

1263

1219

1168

1070

780

592

97

FLSB

27

 

MED

HI

1596

1569

1521

1468

1392

1301

1204

1087

811

604

or

 

97

FLSF

27

HI

1743

1659

1615

1505

1425

1341

1236

1106

809

582

CFM

 

with

 

Coil

 

LO

1067

1017

978

942

889

805

758

703

661

518

98

8W7W

OP

 

MED

LO

1268

1229

1199

1158

1109

1075

1012

826

675

536

with

 

Cabinet

MEDIUM

1374

1343

1311

1278

1224

1163

1053

812

708

524

97

FSOB

27

MED

HI

1549

1481

1409

1338

1258

1189

1087

848

669

481

HI

1611

1529

1460

1383

1297

1199

1115

889

708

578

CFM

 

with

 

Coil

 

LO

1104

1085

1025

979

936

882

786

719

682

580

98

8W12W

OP

 

MED

LO

1309

1266

1232

1197

1156

1119

1074

1010

790

606

with

 

Cabinet

MEDIUM

1429

1390

1350

1323

1281

1234

1203

1124

801

629

97

FLSB

39

 

MED

HI

1607

1573

1539

1497

1430

1332

1256

1152

815

637

or

 

97

FLSF

39

HI

1751

1663

1607

1533

1455

1372

1270

1160

811

619

CFM

 

with

 

Coil

 

LO

1104

1059

1023

974

935

902

841

723

676

563

98

8W12W

OP

MED

LO

1285

1246

1211

1175

1126

1104

1065

874

711

561

 

with

 

Cabinet

MEDIUM

1404

1350

1327

1294

1251

1211

1145

1005

718

535

97

FSOB

39

MED

HI

1601

1538

1468

1400

1327

1241

1148

888

719

541

HI

1725

1613

1530

1442

1360

1283

1190

1088

739

576

CFM

 

with

 

Coil

 

LO

1111

1072

1019

976

931

877

781

712

680

548

98

8G12W

OP

 

MED

LO

1289

1255

1226

1185

1143

1105

1066

938

732

556

with

 

Cabinet

MEDIUM

1415

1367

1345

1308

1270

1226

1170

1072

751

573

97

FLSB

39

 

MED

HI

1594

1571

1519

1449

1380

1294

1205

1043

736

551

or

 

97

FLSF

39

HI

1716

1643

1563

1511

1411

1317

1228

1088

748

596

CFM

 

with

 

Coil

 

LO

1084

1038

996

952

899

813

748

705

823

494

98

8G12W

OP

MED

LO

1262

1227

1187

1150

1112

1067

1014

775

621

488

 

with

 

Cabinet

MEDIUM

1373

1341

1314

1265

1207

1134

1032

807

638

489

97

FSOB

39

MED

HI

1513

1455

1373

1309

1247

1150

1067

793

672

509

HI

1557

1484

1417

1337

1271

1172

1055

835

885

533

CFM

 

with

 

Coil

 

LO

1106

1072

1026

969

938

878

774

721

676

532

98

8Z12W

OP

 

MED

LO

1299

1266

1222

1186

1139

1100

1057

938

752

539

with

 

Cabinet

MEDIUM

1416

1377

1341

1309

1271

1241

1181

1067

740

539

97

FLSB

39

 

MED

HI

1603

1588

1540

1476

1390

1336

1232

1095

748

545

or

 

97

FLSF

39

HI

1741

1667

1607

1532

1435

1350

1253

1148

1165

558

CFM

 

with

 

Coil

 

LO

1088

1019

1007

967

924

870

824

716

621

507

98

8Z12W

OP

MED

LO

1270

1240

1200

1143

1110

1077

990

747

612

496

 

with

 

Cabinet

MEDIUM

1371

1340

1303

1265

1210

1138

1019

796

627

506

97

FSOB

39

MED

HI

1555

1487

1424

1331

1270

1148

1037

792

675

494

HI

1613

1543

1445

1385

1279

1200

1083

924

700

507

EXTERNAL STATIC PRESSURE (ESP) INCHES WC DUCT

CFM

NO

COIL

 

 

Table 5: Blower Performance -10 X 9 Morrison Wheel - 3/4 HP 5 SPD CONSTANT TORQUE Motor 
(With Air filters) 

Summary of Contents for E30 SERIES

Page 1: ...Torque Motor 14 9 Replacement Parts List 3 4 HP Constant Torque Motor 19 5 Blower Performance 3 4 HP Constant Torque Motor 15 CONTACT INFORMATION Contact us by mail Manufactured and Distributed by Mo...

Page 2: ...block or obstruct air openings used for ventilation and cooling of the furnace electrical components 8 Refer to the furnace rating plate for the furnace model number for the operating specifications...

Page 3: ...an The furnace s best friend is a qualified service technician If the unit gives any indication of improper operation call the service technician The service technician is allowed to perform the norma...

Page 4: ...of the furnace to make sure there are no flammable materials in the area If you smell vapors of any kind DO NOT turn on the power to the furnace until vapors have been ventilated and removed from the...

Page 5: ...s on the center shelf Refer to Figure 6 10 Push the upper door forward and tighten with the thumb screw until the door is secured to the cabinet Refer to Figure 6 11 Follow the instructions to Turn On...

Page 6: ...ted as to how to clean and reinstall filters washable or replaceable filters for good preventive maintenance Care must be taken that the edges of the washable or replaceable filter are resting on the...

Page 7: ...cause serious injury if clothing or body parts get caught in the moving part The manufacturer or distributer will not be responsible for any repairs due to improper parts changes improper maintenance...

Page 8: ...trol Box Cover Figure 8 Blower Assembly and Mounting Screw Location 8 Check the blower wheel for dust and debris Use the brush and the vacuum cleaner to remove any dust or debris from the wheel Be car...

Page 9: ...heating or cooling operation 9 Thermostat Y Circuit The thermostat Y circuit is used for cooling or high speed indoor fan operation When 24 VAC is placed on the thermostat Y circuit the 24 vac is sen...

Page 10: ...heck all wiring connections especially on any of the components to ensure they are securely fastened If you have 240 VAC coming out of the control box circuit breakers and you have 24 VAC between the...

Page 11: ...tactor check for 24 VAC between the A1 and A2 terminals If 24 VAC is present then replace the heater contactor L1 L2 T1 T2 A 1 A 2 Figure 11 Heater Contactor Terminal Designations Blower Motor FLA 1 3...

Page 12: ...2 741 615 466 LO 764 689 586 507 460 399 332 MED LO 855 807 733 632 571 521 478 416 367 MEDIUM 990 923 878 825 741 672 628 574 520 440 MED HI 1085 1031 988 929 878 789 725 663 603 474 HI 1291 1247 120...

Page 13: ...56 630 494 with Cabinet MEDIUM 1251 1216 1170 1134 1079 1045 1009 860 685 570 97 FLSB 27 MED HI 1450 1410 1380 1335 1303 1221 1139 1056 737 580 or 97 FLSF 27 HI 1549 1506 1457 1410 1335 1246 1165 1056...

Page 14: ...1245 1137 1012 679 551 or 97 FLSF 39 HI 1570 1531 1488 1415 1344 1279 1170 1070 736 562 CFMwith Coil LO 851 813 759 708 618 555 523 458 394 362 98 8Z12W OP MED LO 1021 982 934 884 837 740 684 636 573...

Page 15: ...4 1065 874 711 561 with Cabinet MEDIUM 1404 1350 1327 1294 1251 1211 1145 1005 718 535 97 FSOB 39 MED HI 1601 1538 1468 1400 1327 1241 1148 888 719 541 HI 1725 1613 1530 1442 1360 1283 1190 1088 739 5...

Page 16: ...TON ACCESSORY BLOWER 86MH0025 3 4 HP PSC 5 TON ACCESSORY BLOWER 86MH0026 3 4 HP CONSTANT TORQUE 5 TON ACCESSORY BLOWER 86MH0027 21 1200 CFM BROKE DOWN COOLING COIL CABINET 97 FLSB 21 21 1600 CFM BROK...

Page 17: ...019P R68AB0019P 6 HEATER CONTACTOR 2 R68AB0019P R68AB0019P R68AB0019P 7 TRANSFORMER R68AA0003 R68AA0003 R68AA0003 R68AA0003 R68AA0003 R68AA0003 8 CIRCUIT BREAKER 1 R68BAD014 R68BAD016 R68BAD018 R68BAD...

Page 18: ...HEATER CONTACTOR 2 R68AB0019P R68AB0019P R68AB0019P 7 TRANSFORMER R68AA0003 R68AA0003 R68AA0003 R68AA0003 R68AA0003 R68AA0003 8 CIRCUIT BREAKER 1 R68BAD015 R68BAD017 R68BAD018 R68BAD015 R68BAD018 R68B...

Page 19: ...AA0003 R68AA0003 R68AA0003 R68AA0003 R68AA0003 8 CIRCUIT BREAKER 1 R68BAD015 R68BAD017 R68BAD018 R68BAD015 R68BAD018 R68BAD018 9 CIRCUIT BREAKER 2 R68BAD014 R68BAD013 R68BAD017 10 LOW VOLTAGE TERMINAL...

Reviews: