CLEARANCE REQUIREMENTS
ALCOVE INSTALLATION
WITH DOUBLEWALL CONNECTOR
3112
3142
A. Sidewall to unit
B. Backwall to unit
D. Sidewall to connector
E. Backwall to connector
G. Unit to ceiling
H. Floor to ceiling
20” (508 mm)
9” (229 mm)
25” (635 mm)
11.5” (292 mm)
33” (838 mm)
60” (1524 mm)
16” (406 mm)
8” (203 mm)
23” (584 mm)
11” (279 mm)
33” (838 mm)
62” (1575 mm)
Flooring requirements
Combustible floor must be protected with non-combustible material beneath the unit and extend-
ing 16-in (450-mm Canada) to the front and 6-in (200-mm Canada) beyond each side of the fuel/
ash removal opening. For horizontal cimney connectors, non-combustible material must be place
beneath the connector and 2-in to each side.
You must ensure that the floor can hold the weight of the stove comfortably.
If using rear exit the floor protection must extend beneath the chimney connector and 2-in
beyond each side.