1.6 Mobile Home Installation
The Morsø 3112 & 3142 can be installed in a mobile home if equipped with an outside com-
bustion air kit, a terminal cap with a spark arrestor, and if it meets the following installation
requirements:
- The stove must be secured to the mobile home structure by bolting through the hearth
pad and into flooring.
- The stove must be installed with a listed Type HT chimney connector, HT Chimney, and
terminal cap with spark arrestor. Never use a single wall connector (stovepipe) in a mo-
bile home installation.
- Floor protection requirements in section 1.5 must be followed precisely.
- Follow the chimney and chimney connector manufacturer’s instructions when installing
the flue system for use in a mobile home.
- Outside air kit should be installed according to installation guide in the kit.
- Intake air piping can be installed through the floor into a vented crawl space or through
the wall of the residence to obtain outside air.
- Install in accordance with 24 CFR, Part 3280 (HUD).
- NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5’
from ground level for transportation purposes.
WARNING:
NEVER DRAW COMBUSTION AIR FROM A WALL,
FLOOR OR CEILING CAVITY OR FROM ANY EN-
CLOSED SPACE SUCH AS AN ATTIC OR GARAGE.
DO NOT INSTALL IN A SLEEPING ROOM.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MO-
BILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED (I.E., DO NOT
CUT THROUGH FLOOR JOIST, WALL STUD,
CEILING TRUSS, ETC.) DO NOT USE A GRATE
TO ELEVATE FIRE - BUID FIRE DIRECTLY ON
HEARTH.
Note:
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof
cover.
Fresh Air Inlet
Unless there is deemed to be sufficient ambient leakage of air into the room via doorways, windows
and the like, a dedicated fresh air inlet will be needed. This inlet should have 2 square inches (1250
square mm) of free air space. This is particularly importAnt where the room is well sealed, or where
an extractor hood or ventilation system disturbs the natural air pressure. Such an inlet should not
be on a wall that is usually subject to negative pressure from normal wind pattern. Avoid placing the
inlet directly across the room from the stove, thus causing a cold air draft.