Page 1: ...MORSØ JERNSTØBERI A S DK 7900 NYKØBING MORS E Mail stoves morsoe com Website www morsoe com Installation and Operating Instructions 3112 3142 For use in North America ...

Page 2: ...gratulations on the purchase of your new Morsø stove Morsø which is the largest supplier for the Dan ish market has manufactured stoves of the highest quality since1853 By following the instructions over leaf we are sure that you will enjoy the use and the benefits of your stove for many years to come Read this entire manual before you install and use your new room heater If this room heater is no...

Page 3: ... 1990 The Morsø 3112 3142 have been tested by OMNI Test Laboratories Inc The test standards are ANSI UL 1482 for the United States and ULC S627 for Canada The stove is listed for burning wood only Do not burn other fuels Under specific test conditions this heater has been shown to deliver heat at rates ranging from 9 300 to 28 500 Btu s Cast iron Cast iron is a live material There are no two ovens...

Page 4: ...t connect to any air distribution duct or system Important If the installation instructions are not followed carefully it may cause dan gerous situations like chimney and house fires Follow the instructions carefully and do not deviate from them as it may cause injuries to people or property 1 1 Checking loose parts in the stove After unpacking check that the center grate in the centre of the fire...

Page 5: ...le chimney stack use one flueway per appliance Use a residential type masonry or listed type HT factory built chimney High Temperature H T Chimney Standard UL 103 1985 2100º F for the USA and High Temperature 650ºC Standard ULC S 629 for Canada The internal dimensions of the chimney connector and chimney must not be less than 6 inch es diameter or equivalent cross section and should not be signifi...

Page 6: ...e wall connectors must be tested and listed for use with solid fuel burning applianc es Single wall connectors should be made of 24 gauge or heavier gauge steel Do not use galvanized connector it cannot withstand the high temperatures that smoke and exhaust gases can reach and may release toxic furnes under high heat The connector must be 6 inches 150mm in diameter If possible do not pass the chim...

Page 7: ...7 ...

Page 8: ...circulates around the stove and out into the room CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION SINGLEWALL CONNECTOR 3112 3142 A Sidewall to unit B Backwall to unit C Cornerwall to unit D Sidewall to connector E Backwall to connector F Cornerwall to connector 20 508 mm 12 305 mm 17 432 mm 25 635 mm 14 5 368 mm 23 584 mm 16 406 mm 9 228 mm 13 330 mm 23 584 mm 12 305 mm 19 483 mm CLEARANC...

Page 9: ... opening For horizontal cimney connectors non combustible material must be place beneath the connector and 2 in to each side You must ensure that the floor can hold the weight of the stove comfortably If using rear exit the floor protection must extend beneath the chimney connector and 2 in beyond each side Distance to furniture The recommended minimum dis tance from stove to furniture is 30 inche...

Page 10: ...p sections of chimney must be removable to allow maximum clearance of 13 5 from ground level for transportation purposes WARNING NEVERDRAWCOMBUSTIONAIRFROMAWALL FLOOR OR CEILING CAVITY OR FROM ANY EN CLOSEDSPACESUCHASANATTICORGARAGE DO NOT INSTALL IN A SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF THE MO BILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED I E DO NOT CUT THROUGH FLOOR JOIS...

Page 11: ... and heat output wood fuel should contain no more than 20 moisture this can easily be checked by using the Morsø Moisture Meter part 62929900 To naturally season wood fuel stack and store it under cover in an airy location where fresh air can move through each piece Some soft woods may take as little as one good summer to sea son whereas harder woods such as oak maple and elm may require seasoning...

Page 12: ... has been fitted with a removable handle When not in use the handle can be stored using the lug behind the right leg of the stove 2 2 Lighting and loading intervals When first lighting the stove a large volume of air is needed When the stove is cold you should leave the door open an inch or two for the first few minutes and open the primary air supply completely While the door is open do not leave...

Page 13: ...ove 6 Lay three pieces of wood see dimensions above onto the embers Leave half an inch 1 cm or more between each piece Place the ends of your logs towards the open ing but not too close to the front 7 Close the door Leave the primary air supply fully open 8 After a few minutes and adjust the primary air supply to suit your heating requirements 9 Anticipate each refueling remembering to add a modes...

Page 14: ...450 C 750 F it is considered as over firing and may cause premature wear and tear of the stove To help gauge the correct running temperature of your stove we recommend you use the Morsø FlueGasThermometer part 62901200 TheFlueGasThermometermagneticallyattachesonto thestovepipeapprox20cm 8 abovethestove stopplateandmeasuresthesurfacetemperature of the stove pipe Please see your authorized Morsø Dea...

Page 15: ...st will burn off as temperatures increase For heavier deposits that will not burn off use Morsø glass cleaner applied when the glass is cold in accordance with the instructions Never use abrasive cleaners on the glass surface Reasons for dirty glass Fuel too wet Logs too large or not split Combustion temperatures too low Replace broken glass immediately Do not operate your stove if the glass in th...

Page 16: ...g important To reduce the risk of breaking the glass avoid striking the glass or slamming the door Internal service parts The flame path equipment consisting of the ashpan grate firebricks glass baffle and flue collar are subject to the extremes of heat produced by the fire From time to time one or other of these parts may need replacing as a matter of routine maintenance NOTE The flame path equip...

Page 17: ...with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally disperded they should be retained in the closed container until all cinders have thoroughly cooled Return the ash pan to its original position in the sto...

Page 18: ...for any period of time clean it out thoroughly and leave the spinner slightly open to allow airflow Make sure that the flue does not allow rainwater to come anywhere near the stove install a chimney cap but do not block off the flue completely These measures should ensure there is a slight movement of air through the stove and that the body of the stove remains dry right into the corners Any ash l...

Page 19: ...19 3 5 Parts diagram for model Morsø 3112 3142 ...

Page 20: ...2700 41 Glass fitting 54146361 54146361 42 Fitting for flue collar 44256700 44256700 46 Distance tube 545003 545003 48 Bush brass 752621 752621 50 Baffle plate stainless 71312300 71312300 51 Poker 541075 541075 52 Door handle 752625 752625 60 Ceramic glass 79310000 79310000 61 Stone side 79311300 79311300 63 Stone back 79311400 79311400 64 Tightening tape 79074500 79074500 71 Black steel set screw...

Page 21: ... Steel box nut 735008 735008 121 Stainless pressure spring 79048600 79048600 122 Screw 73960800 73960800 123 Screw 731635 731635 124 Screw 731630 731630 125 Screw 791835 791835 126 Screw 73861700 73861700 127 Airtightbox 71313800 71313800 128 Air Duct back 443143xx 443143xx 129 Screw 731616 731616 131 Air Tight Adapter 71360600 71360600 144 Washer 79190000 79190000 146 Fitting without thread f cov...

Page 22: ...22 G ...

Page 23: ...oduction process and detailed measures have been put into place at all key stages of the build Accordingly provided that the stove has been supplied by an authorised Morsø dealer Morsø will offer a 10 Year Manufacturers Guarantee against manufacturing defect to any of the main exterior body parts of its stoves Read more about Morsø 10 years guarantee product registration card and REGISTER your new...

Page 24: ...Light with dry kindling use 1 2 kg Leave the door ajar and stay close to the stove during the lighting phase Good layer of embers Be certain to have a good layer of em bers before refilling The wood should light within 2 minutes If the logs do not ignite it may in an extreme case cause the flue gases to ignite which may pose a risk to material damage or personal injury Refuelling When refuelling u...