 Carriage-Mounted Drum Racker

Operator’s Manual for Morse Model 289C MORStak

TM

 Carriage-Mounted Drum Racker

Serial number 269119 to ______

morsedrum.com

Copyright 2019  -  Morse Mfg. Co., Inc. 

 

Form OM289C (269119-______)  (Updated 14 Jun, 2019 11:28 AM)

   

 

5

To Take a Horizontal Drum from a Rack and Place Upright on the Floor

Tilt the drum holder assembly to the horizontal position and 

1. 

rotate the grip pad hand crank counter-clockwise to the 

full open position.  Raise the drum holder assembly to the 

approximate elevation of the drum to be taken down. Drive the 

MORStak

TM

 attachment up to the drum and adjust the height 

of the drum grab, if necessary, to clear the drum walls & rack. 

Drive the MORStak

2. 

TM

 forward until the “bridge” meets the 

head of the drum. (see Figure 3.2).  

 

 

 

DAnGeR

 

- It is Critical that the Bridge of the Drum  

 

Holder Assembly is Fully Pressed Against the Top of  

 

the Drum Before Lifting from the Horizontal Position.

  

 

If the top of the drum is not seated against the bridge,   

 

the rim grip pads may not properly engage, and the drum  

 

can slide off.

 

 

Note: There are interlock switches built into the drum holder 

which are intended to prevent tilting when the drum is not 

properly positioned. The true safety of this operation, however,  

depends on the operator correctly positioning the drum in the  

drum holder, and verifying proper engagement of the rim grip pads. 

Figure 3.2

 

1. 

WARnInG

 

- Stay Clear of Raised Drum.

 NEVER allow anyone to be below any part of a raised drum handler or drum. 

 

 

 

 

 

WARnInG

 

- Do NOT Disengage the Grip Pad When Vertical Drum is Off the Ground.

 When the drum is in the    

 

vertical position, lower the drum to the floor before releasing the grip pads.

 

 

 

After ensuring that the area in front of the MORStak

2. 

TM

 is clear, tilt the drum to the horizontal position by pushing the “HORZ” 

button on the pendant.  Do not raise the drum until you have reached the racking area.  It can be unsafe to move the 

MORStak

TM

 with a raised drum. 

After the drum has been tilted to the horizontal position, rotate the grip pad clamp hand crank counter-clockwise to the full open 

3. 

position.  This will allow the drum to be cradled by the two parallel drum-supporting bars and allow it to be racked horizontally.   

 

 

 

Note: There are interlock switches built into the drum holder which are intended  

 

to prevent tilting when the drum is not properly positioned.  If the grip pad or the  

 

top drum rim is not properly positioned, the tilting function is disabled. 

 

Drive the unit to the drum storage area and raise or lower the drum to a height that is a couple inches higher than the shelf 

4. 

height.  Drive the unit into the storage position and carefully lower the drum onto the rack.  The two parallel drum-supporting 

bars should be just below the walls of the drum but still above the rack.  This will allow clearance to withdraw the MORStak

TM

 

and leave the drum in the storage position.