background image

The Specialist In Drum Handling Equipment

Models 525M-T

Vertical-Lift, 106”, Spark Resistant Parts,  

Scale-Equipped, Manual Lift and Tilt

Operator’s Manual for Morse Models 525M-T

with Serial Number 249855 to ______

morsedrum.com

Copyright 2022  -  Morse Mfg. Co., Inc. 

 

Form OM525M-T (249855-______) 

(Updated 2 Mar, 2022) 

2

Safety Information

 (continued)

DANGER 

- Indicates a situation which, if not avoided, 

will

 result in serious injury or death. 

This signal word is limited to the most extreme situations.

WARNING 

- Indicates a situation which, if not avoided, 

could

 result in serious injury or 

death.

CAUTION 

- Indicates a situation which, if not avoided, can result in damage to the machine.

CAUTION 

-

 

Do NOT transport with drum raised. 

 

Always lower the drum holder to lowest position before transporting.

DANGER 

- Stay well clear of power lines. 

 

Never approach a power line. Current in a high voltage line may arc some distance from the wire to the steel framed, 

grounded machine.

WARNING 

- The Vertical-Lift Drum Pourer is designed to handle one drum of the types listed at the top of page 

3 - Machine Description. DO NOT attempt to handle any other type of drum or object.  DO NOT exceed the weight 

capacity of 800 Lb. (363 kg).

WARNING 

- Level floors only. 

 

For operation only on clean, level floors of suitable bearing capacity. Do not use on sloped surfaces, ramps, irregular or 

debris strewn floors.

WARNING 

- Do NOT modify the unit. 

 

Under no circumstances should any modifications be made to the Morse machinery without factory authorization. Any 

modifications may void the warranty. This machine was designed to perform a specific job and alterations may result in 

injury to operator or machine.

WARNING 

- No loose fitting clothing. 

 

Wear close-fitting clothing and safety equipment appropriate to the job. Loose fitting clothing may become caught on 

the machinery and cause severe personal injury.

WARNING 

- Hydraulic fluid under pressure can be hazardous. 

 

Escaping hydraulic fluid under pressure can penetrate the skin, causing serious injury. Avoid the hazard by relieving 

pressure before disconnecting hydraulic lines. Keep hands and body away from pinholes and nozzles, which eject fluid 

under high pressure. Use a piece of cardboard to search for leaks. If an accident occurs, see a doctor immediately and 

inform them of the nature of the accident.

CAUTION 

- Wear safety shoes. 

 

Wear safety shoes with non-slip soles and hard toe protection.

WARNING: 

This product can expose you to chemicals including barium sulfate, cobalt, titanium dioxide, and 

2-methylimidazole, which are known to the State of California to cause cancer, and bisphenol-A, which is known to the 

State of California to cause birth defects or other reproductive harm.  

For more information go to 

www.P65Warnings.ca.gov

Summary of Contents for 525M-T

Page 1: ...op to lift by Attach loop to an overhead crane and raise slowly Limited 2 Year Warranty Morse drum handling equipment is guaranteed against defects in workmanship or materials for two years when used properly within its rated capacity Warranty does not cover wear from normal use or damage from accident or abuse Motors and other purchased parts carry the warranties of their manufacturers For warran...

Page 2: ...itable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do NOT modify the unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to operator or machine WARNING No loo...

Page 3: ...on EXISTING manual tilt drum handler 55 30M Series Spark Resistant Diameter Adapters for drum with diameter smaller than 22 56 cm To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to ...

Page 4: ...g floor lock handle toward operator until it locks in down position activates the floor lock When floor lock is activated it prevents unwanted free wheeling of unit Floor conditions determine effectiveness of floor lock Operator should verify its holding action before depending on it to hold Drum Holder Assembly MORCINCHTM Drum Holder assembly saddle is the component on Vertical Lift Drum Pourer i...

Page 5: ...tion NOTE Do not allow drum to impact on floor pouring station etc or spill or damage could occur CAUTION Do NOT transport with drum raised ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING Unit can become unstable when transporting with raised load 5 Lift drum to desired pouring height Operate tilt control as described in Machine Description Controls to adjust drum attitude Floo...

Page 6: ...adjust or replace parts as necessary to prevent failure and maintain proper function 3 Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level of the hydraulic fluid Replace any parts that show signs of wear 4 Grease wheel bearings periodically Oil or grease all moving parts including the gears and sprockets in the tilt drive and the ratchet and pawl 5 Worn ...