background image

5

3

Switch the steam switch 

to on and

this will now illuminate.

Steam trigger

WARNING: At the start water may

be ejected. Aim the steam safely. Start
by releasing the steam into a bucket
or sink.
1

Ensure the safety lock 

¤

is off. When

the lock is pushed towards the rear the
trigger cannot be activated. Push the
lock forward to release the steam trigger.

2

When you press the steam trigger, steam
will be emitted from the nozzle. 

H

3

There will be an initial delay of a few
seconds before the water reaches the
boiler. This delay is indicated by the
pump noise and reduces as water enters
the system.

IMPORTANT: On the first use it may take

up to 30 seconds before steam is released.
If steam is not released within 30 seconds
remove and refit the tank, then re-try.

4

Keep the steam trigger pressed and
direct the steam at the surface to be
cleaned, removing the dirt by moving the
steam jet backwards and forwards over
the area.

5

To stop the steam jet, release the steam
trigger.

There will be a delay before the steam

ceases as the remaining water in the
system is expelled.

WARNING: This is normal. Make

sure the steam nozzle is safely
held/located during this period.
6

When the water reaches a low level the
pump will click, this is due to air being
pumped instead of water. Stop using the
appliance, locate the steam nozzle in a
safe location and refill the tank. It is not
necessary to wait for the appliance to
cool down.

IMPORTANT: If the pump is run dry for a

long period it may become air blocked. If
this happens, switch off or leave the unit to
fully cool before re-trying.

Attaching tubes 
and handle

WARNING: Allow all parts to cool

and make certain steam has stopped
before attempting to fit or change any
accessories.
1

Pull the flap down that covers the inlet.
Push the plug firmly into the inlet with
the arrow facing upwards 

I

.

2

Attach the desired accessory, i.e. large
floor brush, jet nozzle or the extension
tube directly to the hose handle
depending on the application.

H

I

70460 Rev 2  10/8/04  10:44 AM  Page 5

Summary of Contents for 70460 GRIMEBUSTER INSTANT STEAM CLEANER

Page 1: ...s in the tank Remove and refit the tank to ensure it is fitted correctly Anti scale cartridge filter To prevent scale build up the anti scale filter must be replaced regularly See page 7 for details A...

Page 2: ...way When using the machine always keep it horizontal Steam must not be directed towards equipment containing electrical components such as the interior of ovens Other safety considerations Do not use...

Page 3: ...team switch Hose inlet socket 3 Illustration Accessories you should have Flexible hose Handle with steam control Extension tubes x 2 Cotton towel x 2 Large floor brush Brush connector Jet nozzle Plast...

Page 4: ...lifting upwards 3 Fill to the max line with water E 4 Replace the filter carefully push fully down then re fit the tank into the back of the machine closing the tank latch securely to lock the tank i...

Page 5: ...s over the area 5 To stop the steam jet release the steam trigger There will be a delay before the steam ceases as the remaining water in the system is expelled WARNING This is normal Make sure the st...

Page 6: ...keep both parts lubricated with petroleum jelly to facilitate connecting and disconnecting 3 To detach the accessories press the release button and pull the items apart Use of accessories Steam handle...

Page 7: ...for recommended replacement intervals This is based on 1 hour use per week In very hard water areas distilled water could also be used WARNING Do not use any descaler solutions in this product Replaci...

Page 8: ...manufacturers instructions For example the anti scale cartridge filter must have been regularly replaced EXCLUSIONS Morphy Richards shall not be liable to replace or repair the goods under the terms...

Reviews: