MORNINGSTAR CORPORATION
17
3.0 INSTALLATION
16
Installation in Hazardous Locations
THIS EQUIPMENT IS ONLY SUITABLE FOR USE IN CLASS
I, DIVISION 2, GROUPS A,B,C and D OR NON-HAZARDOUS
LOCATIONS.
CAUTION:
For hazardous locations, device must be
installed inside an appropriately type rated tool secured
enclosure. Consult with local authority having jurisdiction for
type rating required.
ATTENTION:
Pour les endroits dangereux, le dispositif doit être
installé à l’intérieur un convenablement qualification de type
outil sécurisé enceinte. Consultez les autorités locales
compétentes pour la qualification de type requise.
!
3.2 User Selections
Select a Battery Type
The SunSaver provides a
Battery Select Jumper
to
choose the battery type. See
Section 7.0 Technical
Specifications
for detailed charging information for each
battery type.
The battery select jumper is secured in the terminal block
between terminal #6 and terminal #7 as shown in figure 2a.
The second column in table 1 specifies whether the jumper
should be removed or remain in place, depending on the
desired battery type.
Battery Type
Battery Jumper
Absorption
Float
Equalize
Sealed
Inserted
14.10V
13.70V
N/A
Flooded/
AGM
1
Removed
14.60V
13.70V
14.90V
1. Flooded/AGM absorption value effective with unit serial nos.
2038 0001
and higher
Table 1. Battery Type selection
Figure 2a. Removing the Battery Select jumper.
2
3 .0
!