3.0 INSTALLATION INSTRUCTIONS
3.2 Configuration
The four (4)
Settings Switches
and the B
attery Select
Jumper
adjust the SS-MPPT battery type, load control,
equalization, and communication settings. This section
details the configuration for each setting.
Select a Battery Type
The SS-MPPT provides four (4) different battery types
as shown in table 1 below. Use
Settings Switch
1 and the
Battery Select Jumper
to choose the battery type. See
Section 7.0 Technical Specifications
for detailed charging
information for each battery type.
The battery select jumper is secured in the terminal block
between terminal #6 and terminal #7 as shown in figure 2.
The second column in table 1 specifies whether the jumper
should be removed or remain in place, depending on the
desired battery type.
Battery Type
Battery Jumper
Switch 1
Gel
1
INSERTED
ON (
↑)
Sealed
INSERTED
OFF (
↓)
AGM
1
REMOVED
ON (
↑)
Flooded
REMOVED
OFF (
↓)
(1) Setpoints for this battery type can be modified with custom program-
ming. See
Section 4.7 Programming Custom Setpoints
for more informa-
tion.
Table 1. Battery Type selection