5
3.0 Installation
Required Tools:
Wire cutters / strippers
Drill and
1/8” (3 mm) drill bit
Philips and Flat-head screw drivers
Required Parts (not included):
3A AC in-line fuse
100A DC in-line fuse
Toggle switch (if remote switch is used)
STEP 1 - Mounting
Locate the SureSine on a surface that is protected from direct sun, high
temperatures, corrosive fumes, and water. SureSine may be mounted
horizontally on a flat surface (like a table) or vertically (on a wall). Do not install in
a confined area where battery gasses can accumulate.
Place the SureSine on the surface where it will be mounted and determine where
the wires will enter/exit. Be sure there is sufficient bending room for the wires and
other auxiliary connections. Verify that the mounting screws will not penetrate
wires or other objects located on the opposite side of the surface. With a pencil
or pen, mark the mounting hole locations
With a drill and 1/8” (3 mm) bit, drill pilot holes for each of the four mounting
screw locations marked on the mounting surface.
Place the SureSine onto the surface and align the mounting feet holes with the
four pilot holes. Use the included #10 screws to secure the SureSine to the
surface.