3.0 Network Connections

The Meter Hub allows multiple Morningstar devices to communi-
cate on a MeterBus network. Networked controllers can share data 
and display net system information on a TriStar Meter 2. Table 1 
below lists all Morningstar Devices that can be networked using 
the Meter Hub. Table 1 is divided into two columns. The fi rst col-
umn lists devices that supply power to the MeterBus Network. All 
devices listed in the second column require power 

from

 the Meter-

Bus Network to operate. It is important to understand the power 
requirements of each device connected to a MeterBus network. 
The Meter Hub electrically isolates devices that supply power to 
the MeterBus, preventing grounding problems. Devices that re-
quire power from the network must be connected to devices that 
supply power.

(X)

Supplies Power

(Y)

Requires Power

SunSaver-MPPT-15L

TriStar Digital Meter 2

TriStar-45

TriStar Remote Digital Meter 2

TriStar-60

Relay Driver

TriStar-MPPT-45

TriStar-MPPT-60

Table 1. Morningstar Device MeterBus Power Specifi cations

Summary of Contents for HUB-1

Page 1: ...8 Pheasant Run Newtown PA 18940 USA email info morningstarcorp com www morningstarcorp com Communication Hub UB H ET M ER TM Model HUB 1...

Page 2: ...tion Hub FOR INDOOR USE ONLY MODEL HUB 1 FOR USE WITH MORNINGSTAR METERBUS NETWORKS ONLY E M E T E R H U B E M E T E R H U B Me t e r B u s Co m mu n i c a t i o n Hu b F O R I N DOOR USE ONL Y MODE L...

Page 3: ...ures 6 2 0 Mounting 2 1 Required Tools 7 2 2 Wall Mounting 8 2 3 DIN Rail Mounting 9 3 0 Network Connections 3 1 Networking Rules 12 3 2 Example Networks 14 4 0 Operation 4 1 Status LEDs 17 4 2 Mainte...

Page 4: ...dition Use extreme caution when performing this task CAUTION Indicates a critical procedure for safe and proper operation NOTE Indicates a procedure or function that is important for safe and proper o...

Page 5: ...Meter Hub Operator s Manual 5 1 0 Getting Started 1 1 What s in the Box Meter Hub 9 Operator s Manual 9 Five MeterBus 9 TM RJ 11 Cables 1 meter 3 ft in length Four Mounting Screws 9...

Page 6: ...e 1 Features of the Meter Hub 1 Port Status LEDs Indicates network connection status for each port 2 Input Power Port B Link In Input power for the Meter Hub provided by a device 3 Output Power Port A...

Page 7: ...Meter Hub Operator s Manual 7 2 0 Mounting 2 1 Required Tools Philips screw driver 9 Wire strippers 9 Wire clippers 9 If wall mounting Drill 9 If wall mounting 3 mm 1 8 drill bit 9...

Page 8: ...Be sure there is sufficient bending room for the communication cables Verify that the mounting screws will not penetrate wires or other objects located on the opposite side of the surface Step 3 Hold...

Page 9: ...USE WITH MORNINGSTAR METERBUS NETWORKS ONLY Figure 2 Mounting the Meter Hub on DIN rail Step 1 The DIN rail location should be protected from direct sun high temperatures corrosive fumes and water Do...

Page 10: ...as shown in figure 2 action 1 Step 4 Once the hooks have engaged the upper lip of the DIN rail rotate the Meter Hub so that it is flush and parallel to the DIN rail as shown in figure 2 action 2 Step...

Page 11: ...work All devices listed in the second column require power from the Meter Bus Network to operate It is important to understand the power requirements of each device connected to a MeterBus network The...

Page 12: ...1 4 on the Meter Hub are each isolated from all other ports 9 There is no power output on these ports Ports A B are not isolated from each other 9 One device from column X of table 1 must be connected...

Page 13: ...ces on a MeterBus network must be programmed with a 9 unique MeterBus address The MeterBus address of each device can be modified using a TriStar Meter 2 or MSView PC software See individual product d...

Page 14: ...MORNINGSTAR METERBUS NETWORKS ONLY TriStar Meter TriStar Figure 3 Small Network Diagram A simple two TriStar system with meter is shown in figure 3 above The TriStar on Port 1 is electrically isolated...

Page 15: ...ith Meter Meter TriStar Relay Driver TriStar Figure 4 Medium sized Network The Medium sized network shown in figure 4 includes three TriStars one Relay Driver and two meters There can be a maximum of...

Page 16: ...NINGSTAR METERBUS NETWORKS ONLY Link Out Link In TriStar Lin 1 3 4 5 6 7 8 9 10 X Y Figure 5 Multiple Meter Hub Network For large systems multiple Meter Hubs can be connected via the Link In Link Out...

Page 17: ...nection to each port The Status LED on Port B indicates power status for the Meter Hub The Meter Hub must be powered through Port B for correct operation Status LED ON Green The port is powered with a...

Page 18: ...hout the need for user intervention However the operator should perform the following tasks annually to ensure continued operation Verify that the Status LEDs indicate normal operation 9 Check all net...

Page 19: ...om column X is required to power the port Try a different network cable 9 Make sure the device itself has power 9 Connect the device to a different Meter Hub port 9 Problem The Status LED is ON for ea...

Page 20: ...rningstar will pay the return shipping charges if the repairs are covered by the warranty WARRANTY EXCLUSIONS AND LIMITATIONS This warranty does not apply under the following conditions Damage by acci...

Page 21: ...old plated Enclosure Type 1 indoor rated Compatible DIN rail 35 mm standard Environmental Operating Temperature 40C to 60C Storage Temperature 55C to 85C Humidity 100 NC Tropicalization conformal coat...

Reviews: