19
7.0 TECHNICAL SPECIFICATIONS
ELECTRICAL:
♦
Maximum Solar Voltage
.............600 vdc
♦
Maximum Solar Current
............. 50 adc
♦
GFPD-600V Supply Voltage
Range
........................................... 10-72 vdc
♦
Ground-Fault Current Trip
Threshold
....................................300mA +/- 10%
♦
Self-consumption
........................<1W
♦
Transient Surge Protection
........3000W Battery and 1500W Signal
Port
ELECTRONIC PROTECTIONS:
♦
Reverse Polarity
♦
Disconnected Feedback Signal Circuit Detection
MECHANICAL:
♦
Dimensions (in/cm)
....................... 14.1 x 8.7 x 4.2 / 35.7 x 22.1 x 10.6
♦
Enclosure
.......................................Type 1 Indoors
♦
Weight
........................................... 8.9 lbs / 4.04 kgs
♦
Aperture Diameter
........................0.79 in. (20.0 mm)
♦
Breaker Power Posts
....................1/4 in. - 20 Studs
♦
Recommended Breaker Power Post
Nut Torque
....................................30-35 in-lb (3.4-4 Nm)
♦
Recommended GFPD-600V
Sensing Unit Terminal Torque
....
...3.5 in-lb (0.4 Nm)
♦
GFPD-600V Sensing Unit - Minimum
Conductor Temperature Rating
....75°C
♦
Battery Wire
..................................33 ft. two-conductor 18 AWG -
stranded copper or aluminum
♦
Battery Fuse Holder
.......................In-line
♦
Battery Fuse
....................................5A, min. 125 vdc
♦
Trip Signal Wire Harness
................8.5 / 10.5 in. two-conductor
18
AWG stranded copper
♦
Feedback Jumpers
..........................(2)-4.5 in. 600V single-conductor
stranded copper or aluminum
♦
Feedback Signal Wire Harness
......3.5 / 6.5 in. 600V two-conductor
14
AWG stranded copper or aluminum
♦
Mounting (GFPD-600V Module)
....35 mm DIN Rail or Panel
Mount with (2)-#6-32 screws