Description of functioning
t e c h n i c a l
20
The table below shows the gas pressure values at the burner for each model of
boiler:
OUTPUT (kcal/h)
BURNER PRESSURE IN
m
b
OF WATER
GAUGE
BOILER 24KW
Natural
Propane
20382
18
.
0
35
.
0
18060
13
.
3
27
.
0
16340
11
.
2
23
.
0
14620
8
.
6
19
.
0
12900
7
.
0
14
.
8
11180
5
.
3
11
.
9
9460
4
.
0
8
.
6
7740
2
.
3
5
.
8
6536
1
.
3
3
.
2
Ignition
Pressure
4
.
0
8
.
0
Ø In
j
ectors (mm)
1,14
0,75
Important:
It is very important to know that when you are mak-
ing
adjustments to
the gas regulation you may use the values
of this table.
The values should be equal or lower never higher. For
example
if you are making a maximum natural gas regulation the
table says 18
.
0m
b
so you
achieve
18
.
0
mb
or less than
18
.
0
mb
.
I
Changing the gas:
This boiler is designed to function using
PROPANE
GAS or
NATURAL GAS
GAS.
To change the type of gas used, the only com-
ponents that need to be changed are the injec-
tors. The injectors corresponding to the gas to
be used are fi tted as shown in Table 3.
After the injectors have been changed, the gas
is to be adjusted depending on the type used,
as shown in Table 3.
- Maximum pressure adjustment
(@Gas valve)
- Minimum pressure adjustment
(@Gas valve
- Ignition pressure adjustment
(see step 5 T5 adujusting boiler parameters)
using built in auto test feature)
17