Description of functioning
t e c h n i c a l
10
3.1.2.-
Main P.C.B (Part number MCB30
00
)
1
DHW ANTI-FREEZING REL
A
Y (J24)
(NOT USED ON FEB-24ED
3 STAR
)
2
GAS VALVE 1 RELAY. EV1 (J25) (220VAC)
3
GAS VALVE 2 RELAY. EV2 (J25) (220VAC)
4
PUMP REL
A
Y (J17)
5
FAN RELAY (J18)
6
“Opto triac” SPARKS(J25)
7
TRANSFORM
E
R (Ioni
s
ation. 70-80V AC)
8
TRANSFORM
E
R
(MAIN BOARD FUNCTIONS)
9
EARTH
10
MICROPROCESSOR. CONTROL
11
CONFIGURATION
BUTTON
12
(J4) DIGITAL INPUTS (AIR PRESSURE SWITCH,
H.L.
THERMOSTAT, …).
13
(J8)
LOW
PRESSURE SWITCH
14
(J6)
FLOW & RETURN
THERMISTORS, ROOM THERMOSTAT, EXTERNAL PROBE
15
(J22
OR J23) DISPLAY PC
B
(3
PURPLE
WIRES
OR BLACK,
WHITE
&
BROWN
)
16
(J16) MODULATING GAS VALVE (18VDC)
17
(J27) PORT FOR SOTWARE PROGRA
M
18
AUTO TEST PORT
19
SUPPRESSION FILTER
20
SUPPRESSION FILTER
21
MAIN ELECTRICAL SUPPLY CONECTORS (230V, 50Hz)
9
J18
J17
J25
N
N
L
L
L
L
N
N
L
FAN 230V ac
PUMP 230V ac
MAINS
SUPPLY
230Vac
GAS VALVE
EV1 230V ac
EV2 230V ac
SPARK 230V ac
85v ac
18v dc return micro switch
18v dc out micro switch
18v dc return air pressure
18v dc out air pressure
18v dc return HL stat
18v dc out HL stat
18v dc return LPS
18v dc out LPS
TIME CLOCK 0UT 18 vdc
TIME CLOCK RETURN 18vdc
Not Used
Thermistors
Flow
---
Return
L
EARTH
DISPLAY PCB
MODULATING
SOLENOID
J8
J4
J6
16
J23
18
J14
9
1
2
6
21
1
3
4
5
7
8
10
11
NOT USED