background image

15

 

INSTALLATION INSTRUCTIONS AND 

SETTINGS  

РУКОВОДСТВО ПО МОНТАЖУ  И  

ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ 

ЖИНАҚТАУ ЖӘНЕ ТЕХНИКАЛЫҚ 

ҚЫЗМЕТ КӨРСЕТУ ЖӨНІНДЕГІ ҚҰРАЛЫ 

Solely  company  authorized  to  provide  such 
activities  may  perform  the  installation  of  this 
hotplate  and  it  should  be  installed  in  compliance 
with local standards and regulations. 

Плита должна быть установлена и подключена в 
соответствии 

с 

нормами 

и 

правилами, 

действующими в стране Покупателя. 

Плита  Сатып  алушының  елінде  қолданыстағы 
нормалар  мен  ережелерге  сәйкес  орнатылуы 
және іске қосылуы керек. 

CONNECTION TO THE MAINS POWER

 

NOTE: 

The  combined  cooker  is  a  Class  I  appliance  according 
to  the  electric  shock  prevention  degree  and  must  be 
connected to the earthed mains power installation. The 
connections must  be carried out by qualified personnel 
only. 

 

The  appliance  is  fitted  with  power  cord  plug  for 
connection to the mains. 

 

For  appliances  exceeding  2  kW  of  power  it  is 
recommended  to  use  extra  feed  circuit  with  a  16A 
circuit breaker. 

 

Power  socket  to  which  the  appliance  is  connected 
must be accessible at all times. 

 

Faulty  power  cord  must  be  immediately  replaced 
with a new one. 

ЭЛЕКТРОПОДКЛЮЧЕНИЕ ПЛИТЫ 
ВНИМАНИЕ!  

Комбинированная  плита  является  прибором  класса 
I (в соответствии со степенью защиты от поражения 
электрическим  током)  и  должна  быть  соединена  с 
линией 

заземления 

электрической 

сети. 

Подключение 

должен 

осуществлять 

только 

квалифицироаванный специалист. 

 

Прибор  оснащен  проводом  для  подключения  к 
электросети.заземление и токовая защита. 

 

Для  приборов  с  мощностью,  которая  превышает 
2кВт,  рекомендуется  использовать  дополнительную 
коробку с 16 А автоматическим выключателем.  

 

Электророзетка,  в  которую  включается  прибор, 
должна быть доступной в любой момент. 

 

Поврежденный  электропровод  необходимо  срочно 
заменить на новый.

 

ПЛИТАНЫ ЭЛЕКТРГЕ ҚОСУ  
НАЗАР АУДАРЫҢЫЗ!   

Құрамды  плитасы  I-класының  аспабы  болып 
табылады  (электр  тогының  соғуынан  қорғау 
дәрежесіне 

сәйкес) 

және 

электр 

желісінің 

жерлендіру  желісімен  жалғануы  керек.  Іске  қосуды 
тек мілікті маман жүзеге асыруы керек.  

 

Аспап  электр  желісіне  қосылуға  арналған 
сыммен,    жерлендіру  және  ток  қорғауымен 
жабдықталған.    

 

Қуаты  2  кВт-тан  асатын  аспаптар  үшін  16А 
аввтоматты  сөндіргіші  бар  қосымша  қорабын 
пайдалану ұсынылады.   

 

Аспап іске қосылатын электррозеткасы кез келген 
сәтте қолжетімді болуы керек.  

 

Ақауланған 

электрсымын 

жедел 

жаңасына 

ауыстыру қажет.  

IMPORTANT NOTICE 

At  any  range  disassembly  or  assembly  besides  its 
current  use  it  is  necessary  to  disconnect  the  appliance 
from mains and to keep it out of service. 

ВАЖНОЕ ПРЕДУПРЕЖДЕНИЕ 

В  случае  демонтирования  и  монтажа  плиты,  кроме 
стандартного  использования,  необходимо  плиту 
отключить  от  эл.сети  и  обеспечить  выключеное 
состояние. 

МАҢЫЗДЫ ЕСКЕРТУ  

Стандартты 

пайдаланудан 

басқа, 

плитаны 

бөлшектеу  және  жинақтау  жағдайында  плитаны 
эл.желісінен 

ажыратып, 

сөндірілген 

қалыпты 

қамтамасыз ету керек.

  

 

In installation of the appliance, it is necessary to do 
in the light of its duty chiefly the following: 

 

Verification of the correctness of mains connection, 

 

A  check  on  the  duty  of  heaters,  control  and 
governing elements, 

 

Presentation  to  the  client  of  all  functions  of  the 
appliance  and  familiarisation  with  its  service  and 
maintenance. 

При установке прибора необходимо: 

 

обеспечить контроль  правильного подключения  к 
эл.сети 

 

обеспечить  контроль  функции  нагревательных, 
управляющих и регулирующих  элементов 

 

осуществить 

демонстрацию 

заказчику 

всех 

функций  прибора  и  ознакомление  относительно 
обслуживания и содержания     

Аспапты орнату барысында мыналар қажет: 

 

эл.желісіне 

дұрыс 

қосылуын 

бақылауды 

қамтамасыз ету,  

 

қыздырғыш,  басқару  және  реттеу  элементтерінің 
функцияларын бақылауды қамтамасыз ету, 

 

тапсырыс 

берушіге 

аспаптың 

барлық 

функцияларын  көрсетуді  және  қызмет  көрсету 
мен  мазмұнына  қатысты  таныстыруды  жүзеге 
асыру.     

NOTICE:

  

The    range  is  a  Class  I  appliance  according  to  the 
electric  current  injury  prevention  degree  and  must  be 
interconnected with the mains protective conductor. 

ПРЕДУПРЕЖДЕНИЕ: 

Электрогазовая  плита  является  прибором  I  класса 
степени  защиты  перед  травмами  электрическим 
током 

и 

должен 

быть 

соединен 

 

с 

предохранительным кабелем электрической сети.    

ЕСКЕРТУ

:  

Электргаз  плитасы  электр  тогының  соғуынан 
жараққаттану 

алдындағы 

қорғау 

дәрежесінің                       

I-

класының  аспабы  болып  табылады  және  электр 

желісінің сақтандырғыш кабелімен жалғануы керек. 

Summary of Contents for KS 312 MW

Page 1: ...COMBINED ELECTRIC AND GAS COOKER BY KZ RU GB AE44...

Page 2: ...nufacturer to the data on the type label An omni polar curcuit breaker must be installed before the appliance with a between contact spacing of 3 mm or more mark in the following text as main switch B...

Page 3: ...o detect gas leakage If you detect a flaw on the gas installation of the appliance never attempt to repair it by yourself Switch the appliance off cut the gas supply and call authorized personnel to m...

Page 4: ...ructions and recommendations set herewith Do not use pressure vapor cleaner for cleaning the appliance Cooker may only be installed against non inflammable back wall This appliance is not intended for...

Page 5: ...er 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 BEFORE FIRST USE Prior to usage it is necessary to remove any packing material from the range Various parts and components of the range and package are rec...

Page 6: ...ns Do not leave small children without supervision in a room where the appliance is installed This appliance is not intended for use by persons including children with reduced physical sensory or ment...

Page 7: ...he knob repeat the whole procedure of igniting Then set the knob to the desired position SHUTTING THE HOB BURNERS OFF Turn the selected knob to the OFF position and check whether the flame is extinct...

Page 8: ...er presure pot stewing never use hot plates without pots 1 OFF 2 Maximum power 3 Saving 1 2 3 1 2 3 OVEN SWITCHING ON AND OFF Select the desired function of the oven by the oven function knob The knob...

Page 9: ...the bottom surface of the bottom of the furnace and the furnace can be irreparably damaged by this behavior INSERTING OF GRID IN THE OVEN OVEN FUNCTIONS AND APPLICATIONS Oven illumination being on in...

Page 10: ...eratures of the oven space for typical food preparation 50 70 C drying 50 70 C c 50 70 C 80 100 C preservation 80 100 C 80 100 C 130 150 C stewing 130 150 C 130 150 C 180 220 C baking of daught 180 22...

Page 11: ...n door Put the prepared food on a grid Slide the grid into the side guides in such way that loose portion of the grid with fewer cross bars is turned towards you Slide a shallow baking pan filled with...

Page 12: ...asive means producing irremovable damage to the appliance surface HOB GRID Remove the cooking grid from the hob and wash it separately or place it into the dishwasher After washing replace it to fit t...

Page 13: ...nts Following cleaning carefully dry up the oven Clean the oven only when cold Never use abrasive means scratching the enamelled surface Wash the oven appurtenances with a sponge and detergent or empl...

Page 14: ...tion it is necessary to use a bulb T 300 C E14 230 V 25 W 1 Glass cover 2 Lamp 3 Sleeve 4 Oven rear wall T 300 C E 14 230 V 25 W 1 2 3 4 T 300 E14 230 240 B 25 B 1 2 3 4 OVEN Procedure for cleaning of...

Page 15: ...facility Wrapping foil and bags in waste plastic containers LIQUIDATION OF AN APPLIANCE FOLLOWING ITS LIFE EXPIRATION The appliance contains valuable materials which ought to be reused or recycled so...

Page 16: ...16A circuit breaker Power socket to which the appliance is connected must be accessible at all times Faulty power cord must be immediately replaced with a new one I 2 16 I 2 16 IMPORTANT NOTICE At any...

Page 17: ...he insulation LOCATION OF THE RANGE Solely company authorized to provide such activities may perform the installation of this hotplate and it should be installed in compliance with local standards and...

Page 18: ...y be connected to gas supply by only by the authorized personnel Connection must comply with the local standards and requirements The gas supply pipe must be fitted with the accessible gas shut off co...

Page 19: ...e connected by means of a clamp fixed in the back cover opening You will find the fixing clamp in the accessory kit 3 2 1 5 6 4 1 Connection ending 2 Knee 3 Connection hose connection from the right 4...

Page 20: ...ced or increased For butane propane the screw C must be fully screwed in 3 4 3 4 LEVELING THE APPLIANCE Cooker hob must be leveled in horizontal position by means of 4 leveling screws supplied with th...

Page 21: ...tions or improvements of the product EN RU BY KZ Burner Small Medium C Rapid Natural gas G 20 1 3 13 Nozzle diameter mm 0 83 1 12 1 37 Natural gas G 20 2 0 20 Nozzle diameter mm 1 01 1 22 0 77 Propane...

Page 22: ...eater kW 0 75 Bottom heater kW 1 10 Grill heater kW 1 85 Oven light W 25 Min max oven temperature Min max in max 50 250 C Voltage 230 Input power kW 5 45 Input power gas kW 2 90 Gas type Natural gas G...

Page 23: ...ON LIST Model KS 312 MW A More efficient B C D E F G Less efficient B C D E F G A B C D E F G B Energy consumption KWh 0 94 Time min 54 9 Energy consumption KWh Time min Useful volume liters 49 Oven s...

Page 24: ...252E KS 312 MW EN RU BY KZ 2013 08 13 SAP 433784...