5. GENERAL DESCRIPTION

Sling for all kind of patient lift. Made in polyester (100%), especially suitable for water contact, 
strong and breathable, sewn with polyester thread. The border is made by a strong ribbon (100% 
nylon),  which  make  three  eyelets  in  every  extremity  to  guarantee  a  perfect  balance.  The  belt 
continuos and swen around the entire perimeter of the sling to ensure greater toughness. The 
seams are made using high strength polyester yarn.
The RP888 model has the headrest reinforced to increase the head support making the transfer 
more confortable.

1. 

Upper eyelet

2. 

Loops

3. 

Intermediate eyelet

4. 

Loops

5. 

Movement handle

6. 

Label

7. 

Movement handle

8. 

Lower eyelet

9. 

Loops

REF. RP888

1

2

3

4

5

6

6. BEFORE USE

Always verify the sling is in perfect condition, carefully check the seams and the loops.

7. USING WARNING

-  Before use, make sure the device is not damaged: the tissue, the border, the sewing and
  suspension loops must be intact
-  Periodically check for any damage or usury, every 6 month at least, in particular if you often 
  clean the sling
-  Ensure the loops are correctly hooked to the cradle
-  Store and use away from flame or source of heat
-  Do not exceed the maximum load

REF. RP881

1. 

Upper eyelet

2.  Movement handle
3.  Label
4.  Lower eyelet
5.  Loops
6.  Reinforced headrest

Summary of Contents for RP881

Page 1: ...MA RP881_RP888 01 A_05 2016 IMBRACATURE MANUALE D ISTRUZIONE SLINGS INSTRUCTION MANUAL...

Page 2: ...5 DESCRIZIONE GENERALE pag 4 6 PRIMA DI OGNI USO pag 5 7 AVVERTENZE PER L UTILIZZO pag 5 8 MODALIT D USO pag 5 8 1 Da seduti pag 5 8 2 Da sdraiati pag 6 9 MANUTEZIONE pag 6 10 PULIZIA E DISINFEZIONE...

Page 3: ...la sua esclusiva responsabilit che il prodotto fabbricato immesso in commercio dalla stessa Moretti S p A e facente parte della famiglia delle imbracature conforme alle disposizioni applicabili della...

Page 4: ...l acqua antistrappo e altamente traspiranti Una robusta cinghia spinata 100 nylon orla le imbracature e forma ad ogni estremit un occhiello con tre diversi punti di aggancio per assicurare la simmetr...

Page 5: ...orma corretti Per un elenco completo delle imbracature disponibili fare riferimento al catalogo MORETTI In caso di uso di imbracature con un carico massimo differente da quello previsto per il solleva...

Page 6: ...urezza del paziente e del medico si raccomanda di far controllare dal produttore o da un laboratorio autorizzato almeno ogni 6 mesi l idoneit all uso del vostro prodotto 10 PULIZIA E DISINFEZIONE Lava...

Page 7: ...a e istruzioni per l uso modifiche non autorizzate danni di spedizione diversa dalla spedizione originale da Moretti oppure dalla mancata esecuzione della manutenzione cos come indicato nel manuale No...

Page 8: ..._______________________ Acquistato in data______________________________________________________________ Rivenditore ____________________________________________________________________ Via __________...

Page 9: ...NERAL DESCRIPTION pag 11 6 BEFORE USE pag 11 7 WARNING FOR CORRECT USE pag 11 8 HOW TO USE pag 12 8 1 From a sitting position pag 12 8 2 From a lying position pag 12 9 MAINTENANCE pag 12 10 CLEANING A...

Page 10: ...s outlined in the Medical Devices Directive 93 42 EEC and further modifications To this end Moretti S p A guarantees and declares as follows under its own responsibility 1 The devices in question sati...

Page 11: ...ransfer more confortable 1 Upper eyelet 2 Loops 3 Intermediate eyelet 4 Loops 5 Movement handle 6 Label 7 Movement handle 8 Lower eyelet 9 Loops REF RP888 1 2 3 4 5 6 6 BEFORE USE Always verify the sl...

Page 12: ...ter shoulder straps to the spreader bar Move the hoist towards the patient while doing this Fig 3 ATTENTION The long straps are for the legs and the short ones for the shoulders 8 2 From a lying posit...

Page 13: ...the inserting container for municipal waste We recommend to dispose the sling in the appropriate disposal areas for recycling 12 TECHNICAL FEATURES REF RP881 MATERIAL 100 Polyester and Webbing 100 nyl...

Page 14: ...zed alteration shipment damages different from original Moretti shipment or in case of insufficient maintenance as indicated in the manual The warranty doesn t cover components subject to wear and tea...

Page 15: ...______________________ Purchased on date _ ____________________________________________________________ Retailer _ ______________________________________________________________________ Address ______...

Page 16: ...MORETTI S P A Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo Tel 39 055 96 21 11 Fax 39 055 96 21 200 www morettispa com info morettispa com...

Reviews: