Manual Part No: 930006-01
MD Gas Grill
- 11 –
Manual Rev No: 1
Installation (cont.)
Checking and Commissioning (cont.)
ALTHOUGH EVERY APPLIANCE IS TESTED AND SET BEFORE IT LEAVES THE FACTORY, IT IS
IMPORTANT THAT THE INSTALLER RE-CHECKS CERTAIN FUNCTIONS BEFORE LEAVING THE SITE.
CHECK THE GAS PRESSURE AT THE APPLIANCE THUS
: -
The pressure test point is located behind the Grill, on the gas Inlet pipe.
Connect a manometer (U tube) to the test point. Turn on the gas supply and light the Burner. Check that
the pressure reading agrees with that stated on the Data Plate.
SHOULD ADJUSTMENT BE NECESSARY, PROCEED AS FOLLOWS
: -
FOR PROPANE GAS, REFER TO SUPPLIER
.
On the gas governor:
Remove the cap in order to gain access to the pressure adjusting screw.
Turn the pressure adjusting screw clockwise to increase the pressure or anti-clockwise to decrease it.
When the pressure reading is correct, refit the cap to the governor.
Turn the gas supply to the unit
OFF
at the stopcock and disconnect the manometer (U tube). Ensure that
the pressure test point screw is refitted.
Turn the gas supply to the appliance on at the stopcock and leak test the pressure test point.
Burner Aeration
The aeration of all the burners is fixed and does not need adjusting.
Note: -
The grill burner is partially blocked off (approximately a 50mm strip in the centre of the burner) this is
to give even heat distribution across the Toast Rack/Brander Plate.