moog
MSD Servo Drive DC-AC Operation Manual
[
]
Commissioning
41
Id.-No.: CA97554-001 Date: 06/2012
4.4 Integrated operator control unit and
MMC card
The built-in operator control unit permits diagnosis of the MSD Servo Drive. In addition,
use of the MMC card aids serial commissioning without a PC. The operator control unit
comprises the following elements, all located on the front of the device:
•
2-digit 7-segment display (D1, D2)
•
two pushbuttons (T1, T2)
•
MMC slot (X1)
Moog MMCplus cards of type SC-MMC128 can be used (128 MB memory and 3.3
V supply voltage, for further details see MSD Servo Drive Ordering Catalog).
Fig. 4.1 Integrated operator control unit
D1
D2
T2
T1
X1
The following functions and displays are available:
•
Display of device state (see section 5.1.1 starting on page 47)
The device state is displayed after switching on the control voltage. If no input is
made via the keypad for 60 seconds, the display switches back to the device state.
•
Display of device error state (see section 5.1.2 starting on page 47)
If a device error occurs the display immediately switches to show the error code.
•
Parameter setting (display “PA“) (see section 4.4.3 starting on page 43)
Reset device parameters to factory defaults and data set handling by way of the
MMC card
•
Ethernet IP address setting (display “IP“) (see section 4.4.4 starting on page 44)
Setting of the Ethernet IP address and the subnet mask
•
Fieldbus settings (display “Fb“) (see section 4.4.5 starting on page 45)
Setting of fieldbus address for example
•
Firmware update with MMC card (see section 4.4.6 starting on page 46)