background image

MP-201 Multi-Pedal Manual

Firmware v2.0 Addendum

Gate channels and MIDI:

A Gate channel can output a MIDI CC (0-127) and/or a MIDI Note (0-127). The MIDI CC value will be 127 when 
the Gate is turned On, or 0 when the Gate is turned Off.  

If 

MIDINOTE OUT

 is enabled, the channel will output a NoteOn with Velocity 64 when the Gate is turned On, and 

a NoteOff (velocity 0) when the Gate is turned Off.  The MIDI note number which is sent is set by 

MIDINOTE 

OUT

.

If a MIDI CC is enabled for a Gate channel, then the Gate can also be turned On and Off by sending this MIDI 
CC number to the MP-201 on the selected MIDI channel, regardless of the 

GATE

 

SOURCE

.  Any MIDI CC value 

greater than 63 will turn on the Gate if it is Off, and any MIDI CC value 0-63 will turn off the Gate if it is On.

New Channel Modes:

MIDI TO CV

The 

MIDI TO CV

 Channel Mode takes MIDI Notes as input, and puts out a Pitch Control Voltage which is 

adjustable between 0.667 Volts per octave and 1.333 Volts per octave.  The default is 1.0 Volts per octave; this 
is set by the CV SCALE parameter.

One certain MIDI note will always produce a CV output of zero Volts; this is called the Root Note and is set by 
the user, using the 

ROOT NOTE=0V

 parameter.  All other Pitch CV output is calculated relative to this Root 

Note.  

If the MP-201 CV Scale is set to 

UNIPOLAR

 (all CV outputs are restricted to the range 0V to +5V), then the Root 

Note is the lowest note that will play; all MIDI notes below this will also cause the CV output to be zero Volts.  

If the MP-201 CV Scale is set to 

BIPOLAR

 (output voltage range -5V to +5V), then the Root Note sits in the 

middle of the Pitch CV range, and MIDI notes below the Root Note will cause a negative voltage output, down to 
-5V minimum.  

The default Root Note is MIDI Note 48, or C3.  You can transpose by semitones the pitch of the CV output 
relative to the MIDI notes you play, just by changing the Root Note.

PITCH BEND

 - MIDI TO CV channels can also respond to Pitch Bend messages on the selected MIDI channel, 

at full 14-bit resolution. You can set Pitch Bend range from 1 to 12 semitones or 24 semitones, or turn Pitch Bend 
off.

GLIDE MODE

 - allows for analog-style glide between notes.  

OFF

 turns off the Glide feature, 

ON

 causes a glide 

between all notes all the time, and 

LEGATO GLIDE

 causes a glide only between overlapping notes, with no 

glide (instant change in Pitch CV) for disconnected notes.  Legato Glide is excellent for live performance and for 
303-style step-sequences.

GLIDE RATE 

- sets how much glide between notes. Range is 0-4095, but actual glide time depends on the Glide 

Type used.

GLIDE TYPE

 - has four options: Constant Rate, Constant Time, Log, and Exp.  Constant Rate is classic "Moog-

Style" glide; in Constant Rate mode the Glide Rate parameter sets how long it takes for the Pitch CV to change 
by one volt.  This rate of change is constant, so as a result it takes longer to glide between two notes that are far 
apart than it takes to glide between two close-together ones.  

Page | 5

Specifications subject to change without notice

moogmusic.com

Summary of Contents for MP-201 Multi-Pedal

Page 1: ...MP 201 Multi Pedal Manual Firmware v2 0 Addendum ...

Page 2: ...Foot Pedal movement with no lag This way if you record MIDI while sweeping the foot pedal and then play back the MIDI to the MP 201 the channel CV Output will respond exactly as it did the first time when the pedal movement was recorded Note that CV LAG also serves the function of MIDI CC to CV smoothing if enabled Changes to Channel Mode LFO NOISE has been removed from the list of LFO waveforms a...

Page 3: ...hen On again for each new MIDI note If the Gate is controlling an Envelope this will cause the Envelope Generator to fire with each new note played even if other notes are still held These Trigger Modes are designed to behave similarly to the Gate functions of most monophonic analog synthesizers The final GATE SOURCE option is PEDAL CV This mode reads the scaled voltage coming from the MP 201 Foot...

Page 4: ...4095 The duration parameters Hold Attack Decay Release all have a range of roughly 1 millisecond to four seconds while the Sustain level is adjustable between 0V and 5V The HOLD stage begins the moment the Gate is triggered If Hold is enabled the CV output is held at 0V for an adjustable duration between 1 millisecond and 4 seconds before the start of the Attack stage ATTACK sets the duration for ...

Page 5: ...ill play all MIDI notes below this will also cause the CV output to be zero Volts If the MP 201 CV Scale is set to BIPOLAR output voltage range 5V to 5V then the Root Note sits in the middle of the Pitch CV range and MIDI notes below the Root Note will cause a negative voltage output down to 5V minimum The default Root Note is MIDI Note 48 or C3 You can transpose by semitones the pitch of the CV o...

Page 6: ...T sets the amplitude of the Noise signal while Noise Offset sets the DC voltage about which the Noise signal is centered FPEDAL MODE allows you to control either Noise Amount or Noise Offset from the Foot Pedal Heel and Toe Value set the Foot Pedal response range as usual OFF MODE determines what the channel output will be when the channel is turned Off INITIAL sets the output to a preset voltage ...

Page 7: ... to Program Change and Channel Toggle CC messages on the selected Base Channel 6 PGM CHANGE Tx Rx Control sending and receiving MIDI Program Change messages Send Receive Receive Only Send Only or OFF 7 MULTI PGM CHANGE Send All At Once sends Program Change messages for all channels of an MP 201 preset at once and only sends them when the preset is first loaded Send Per Channel sends each MP 201 ch...

Page 8: ... on this new menu 1 SEND ALL PRESETS Send a bank of 100 MP 201 user presets as one SysEx file 2 SEND PRESET Send the currently active preset as a 310 byte SysEx file 3 SEND BULK DUMP Send one large file which contains all 100 User presets and all Global settings 4 SEND FACTORY Send the 40 Factory presets as a SysEx file If you send this file to the MP 201 it will load into the Factory preset memor...

Page 9: ...FS MODE MOMENTARY LATCH if MIDI NOTES VELO TRIGGER OFF 1 127 TRIGGER MODE LEGATO RETRIGGER if PEDAL CV THRESHOLD 0 4095 HEEL VALUE 0 4095 TOE VALUE 0 4095 GATE EG GATE ENVELOPE if ENVELOPE ENV SHAPE LIN LOG EXP COMPLEX if COMPLEX ATTACK SHAPE LIN LOG EXP DECAY SHAPE LIN LOG EXP REL SHAPE LIN LOG EXP HOLD TIME OFF 1 4095 ATTACK RATE 0 4095 DECAY RATE 0 4095 SUSTAIN LVL 0 4095 RELEASE RATE 0 4095 EG...

Page 10: ...LL TIME RISE TIME 1 4095 CHAN OUTPUT CV AND MIDI CV ONLY MIDI ONLY MIDI CC OFF 0 127 MIDI TO CV ROOT NOTE 0V 0 127 CV SCALE 0 667 1 333 PITCH BEND OFF 1 12 Semitones 24 Semitones GLIDE MODE OFF ON LEGATO ON GLIDE RATE 0 4095 GLIDE TYPE CONST TIME LOG EXP CONST RATE NOISE NOISE AMOUNT 0 4095 NOISE OFFSET 0 4095 FPEDAL MODE NOISE AMOUNT NOISE OFFSET HEEL VALUE 0 4095 TOE VALUE 0 4095 OFF MODE INITIA...

Page 11: ...hannel modes CHAN NAME 8 characters INITIALSTATE OFF ON CHANNEL MODE EXPRESSION GATE LFO MIDI TO CV NOISE MIDI CHANNEL OFF 1 16 if MIDI Channel not OFF PGM CHANGE OFF 0 127 BANK CHANGE LSB 0 127 MSB 0 127 Page 11 Specifications subject to change without notice moogmusic com ...

Page 12: ...P CHANNEL 4 EXP 19 MF104LFO FEEDBACK LFO TIME LFO MIX LFO CHANNEL 4 LFO 20 MuRFEXP1 RATE EXP MIX EXP ENVELOPE EXP LFOSWEEP EXP 21 MuRFEXP2 TAP STEP LFO MIX EXP ENVELOPE EXP LFOSWEEP EXP 22 MuRF LFO RATE LFO MIX LFO ENVELOPE LFO LFOSWEEP LFO 23 MF107EXP FREQ EXP WAVE EXP FM AMT EXP MIX EXP 24 MF107LFO FREQ LFO WAVE LFO FM AMT LFO MIX LFO 25 CP251EXP LFO RATE EXP SNH IN EXP MIXER IN EXP MULT1 IN EXP...

Reviews: