3.3 Wiring

The use of crimp “boot lace ferrules” is recommended for the
screw terminals. Allow sufficient cable length so the circuit
card can be withdrawn from its case with the wires still
connected. This enables switch changes on the circuit card
to be made while the card is still connected and operating.
An extra 100mm, for cables going outside the enclosure,
as well as wires connecting to adjacent DIN rail units,
is adequate.

The screw terminals will accommodate wire sizes from 0.2mm

2

to 2.5mm

2

(24AWG to 12AWG). One Amp rated, 0.2mm

2

should be adequate for all applications.

cable gland

100mm Loop

Wires

Enclosure

Radial screen
termination

Cable

Grounded EMI

Preferred Wiring

Page 2 of 6: C70861 Rev A – 01.09

Cable gland

100mm Loop

Cable

Enclosure

Cable

Wire soldered
to screen

Drain wire.

or

(Heat shrink to
cover the screen)

Alternative Wiring

3.4 EMC

The G122-829-001 emits radiation well below the level called
for in its CE mark test. Therefore, no special precautions are
required for suppression of emissions. However, immunity from
external interfering radiation is dependent on careful wiring
techniques. The accepted method is to use screened cables for
all connections and to radially terminate the cable screens, in
an appropriate grounded cable gland, at the point of entry into
the industrial steel enclosure. If this is not possible, chassis
ground screw terminals are provided on the G122-829-001.
Exposed wires should be kept to a minimum length. Connect
the screens at both ends of the cable to chassis ground.

4 Power supply

24V DC nominal, 22 to 28V
75mA @ 24V without a load, 200mA @ 100mA load.

If an unregulated supply is used the bottom of the ripple
waveform is not to fall below 22V.

It is recommended that an M205, 250mA T (slow blow) fuse,
compliant with IEC127-2 sheet 3, be placed in series with the
+24V input to protect the electronic circuit.

R17

1

2

3

4

spare

enable

dither

4-20mA (feedback input)

P gain range

Input 3 to
output amp

1

2

3

4

5

lim

5

10

20

30

50

mA

cmd lag

feedback lead

Input 2 to
error amp

R34

R33

R16

SW5

SW4

SW6

SW2

SW1

1
2

3

4

spare
PR

INT

E or P

SW2 V or

SW5 V or

SW3

Step P.B.

[SW1]

To access the circuit card switches, the circuit card must be
withdrawn from the case. See paragraph 17.

5 Set-up adjustments

Trimpots are all 15 turns.

Plug-in resistors are all “quarter watt” 1% metal film. Two
suitable types are Beyschlag MBB0207 and Roderstein
MK20207.

The amplifier is shipped in the following default state.

top board switches
SW1

1

5mA

off

2

10mA

off

3

20mA

off

4

30mA

off

5

50mA

on

SW2

OUT

I

SW3

STEP

not applicable

SW4-1

P-E

E

SW4-2

CMD LAG

off

SW5

IN 2

V

SW6

1

spare

off

2

PR

on

3

I

Lim

off

4

INT

off

bottom board switch, shown as [ ]
[SW1]

1

spare

off

2

ENABLE

on

3

DITHER

off

4

4-20mA

on

R17: 100k (P gain range 1 to 20)

R34: 100k (input 2 to error amp)

R33: not fitted (input 3 to output amp)

R16: not fitted (feedback derivative)

ON

shown in on position

shown in off position

SW1 + 6 switch positions

Reviews: