PROFINET Cable Diagram
PROFINET Cable Diagram
PROFINET can support line, tree or star device-connection topology. The supported network
topology and maximum number of devices depends on the selected PROFINET mode and
network class. For example, higher performing modes, like PROFINET IRT, require
specialized equipment. For PROFINET network design and installation details, see the
information available at:
CAUTION:
To minimize the possibility of electromagnetic interference (EMI),
all connections should use
shielded
Ethernet Category 5 (Cat 5), or better,
cables.
The following diagram shows an example PROFINET network with the SmartMotors daisy
chained to the master device. An optional "ring" configuration can be created if it is supported
by the selected PROFINET mode and network devices.
PROFINET Bus
Other PROFINET device:
- I/O block,
- Servo drive,
- etc.
PROFINET Master
- PC,
- PLC,
- etc.
Moog Animatics
SmartMotor
Moog Animatics
SmartMotor
Optional ring for cable redundancy*
*Ring configuration requires specific PROFINET modes and supporting devices
NOTE:
Unlike other fieldbus protocols, PROFINET does not require terminators at
each end of the network bus.
Maximum Cable Length
For transmission speeds of 100 Megabits/second on shielded Ethernet Cat 5 cable, EtherCAT
and PROFINET allow cable lengths up to 100 meters between network nodes.
Moog Animatics Class 6 PROFINET Guide Rev. D