Moog Videolarm QMR SERIES Installation And Operation Instructions Manual Download Page 8

!

!

250 ft 

13 

W

300 ft  

10 

16 

W

400 ft  

13 

21 

W

500 ft  

10 

16 

26 

W

600 ft  

10 

12 

19 

31 

W

800 ft  

10 

13 

16 

25 

42 

W

1000 ft  

13 

16 

20 

32 

52 

W

1250 ft  

16 

20 

25 

40 

65 

W

1500 ft  

19 

24 

30 

48 

78 

W

1750 ft  

23 

28 

35 

55 

91 

W

2000 ft  

26 

32 

40 

63 

104 

W

2500 ft  

32 

40 

49 

79 

131 

W

3000 ft  

39 

48 

59 

95 

157 

W

3500 ft  

45 

56 

69 

111 

183 

W

4000 ft 

52 

64 

79 

127 

209 

W

5000 ft 

65 

80 

99 

158 

261 

W

6000 ft 

78 

95 

119 

190 

313 

W

8000 ft 

104 

127 

158 

253 

418 

W

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

Unshielded Twisted-Pair Wire Gauge  (AWG)

Cable

Distance

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

24

22

20

19

18

Unshielded Twisted-Pair Wire Gauge  (AWG)

Distance

24

22

20

19

18

Unshielded Twisted-Pair Wire Gauge  (mm)

Distance

0.5

0.6

0.7

0.8

1.0

13 

W

10 

17 

W

13 

21 

W

10 

16 

26 

W

10 

13 

21 

34 

W

13 

16 

19 

31 

51 

W

17 

21 

26 

42 

69 

W

21 

26 

32 

52 

86 

W

26 

31 

39 

62 

103 

W

32 

39 

49 

78 

129 

W

38 

47 

58 

94 

154 

W

43 

52 

65 

104 

171 

W

51 

63 

78 

125 

206 

W

64 

78 

97 

156 

257 

W

77 

94 

117 

187 

309 

W

102 

125 

156 

249 

411 

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

Cable

Cable

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

75 m 

100 m 
125 m 
150 m 
200 m 
300 m 
400 m 
500 m 
600 m 
750 m 
900 m 

1000 m
1200 m

1500 m 
1800 m 
2400 m 

75 m 

100 m 
125 m 
150 m 
200 m 
300 m 
400 m 
500 m 
600 m 
750 m 
900 m 

1000 m
1200 m

1500 m 
1800 m 
2400 m 

13 

W

12 

18 

W

11 

15 

22 

W

10 

13 

18 

27 

W

13 

17 

24 

36 

W

13 

20 

26 

36 

54 

W

18 

27 

35 

48 

72 

W

22 

33 

43 

60 

90 

W

26 

40 

52 

72 

108 

W

33 

50 

65 

89 

135 

W

40 

60 

78 

107 

162 

W

44 

66 

86 

119 

179 

W

53 

80 

104 

143 

215 

W

66 

100 

130 

179 

269 

W

79 

120 

155 

215 

323 

W

106 

159 

207 

286 

431 

W

2.  Connect the other end of the unshielded twisted pair cable to the NVT receiver.  
     

CAUTION:

  The unshielded twisted pair video signal is polarity dependent. The 

                      positive video wire for each camera MUST be connected to the  
                      positive terminal on the NVT receiver, and negative MUST be  
                      connected to negative.

3.  When using unshielded twisted pair cable you DO NOT need the BNC connector.  All 
four BNC connectors are provided inside the housing for testing purposes. Be sure that 
there is no video connection other than the unshielded twisted pair cable.

Wiring Notes

Wire — What to

 

DO

1.  

DO

 

use point-to-point Unshielded Twisted Pair wire, gauge 24 or thicker, stranded 

or solid, Category 2, 3, 4, or 5. 

2.  The video signal may co-exist in the same wire bundle as other video, telephone, 
data, control signals, or low-voltage power. It is also OK to run NVT video signals in or 
near electromagnetic fields (in accordance with National Electrical Code, local, or other 
local safety requirements).

3.

  

DO

 

measure the wire distance. Use only transceivers that are designed for that 

distance.

4.

  

DO

 

make sure the pair of wires carrying the video signal is sent as a twisted pair 

(e.g. the blue-white/white-blue wires twisted together as a pair), not a “split-pair” (e.g. 
blue-white conductor, part of one pair/orange-white conductor, part of another pair).

Wire — What

 

NOT

 

to

 

DO

1.

 

DO NOT USE SHIELDED TWISTED PAIR WIRE.

 

It will severely degrade the dis-

tance performance. Short runs may be used with some signal degradation (for example 
elevator traveler cables). Multi-pair wire with an overall shield is OK. 

2.

 

DO NOT USE UN-TWISTED WIRE.

 It will reduce the NVT   product’s inherent 

interference immunity.

3.

  

DO NOT

 

allow your installation to have “bridge-taps”, loading coils, talk-battery, or 

MOV type protectors. Bridge-taps are where a twisted pair is connected to two twisted 
pairs (such as an extension phone at home). Bridge-taps cause reflections as the 
signal propagates, resulting in “ghosts” in the video image, and are to be avoided. 

4.  If the phone company is providing the cable runs between buildings, make sure it’s 
“dry copper” i.e. it should have none of the following: dial-tone, 48 volts, loading coils, 
bridge-taps, switching, or long paths to the phone company’s central office and back.

5.  Due to near-end crosstalk, D

O NOT

 

send a transmit and a receive signal in the 

same wire bundle. Exceptions: Less than 1,000 ft (300m), or Category 5 cable, up to 
2,000 ft (600m) are OK.

6.  

DO NOT

 

send “Up-the-Coax” Pan/Tilt/Zoom signals through active (amplified) NVT 

transceivers.

Measure your wire distance

Note:

 

All NVT quoted distance specifications include any coax in the 

run. It is recommended that the wire distance be measured to ensure 
that the capability of the NVT product is correct. 

Wire resistance may be measured with an ohm-meter by shorting 
the two conductors together at the far end, and measuring the 
loop-resistance out and back. Compare your readings with the charts 
below.

7.  For safety, never put NVT signals in the same conduit as high-voltage 
wiring.

8.

  

WARNING

 — 

to reduce a risk of fire or electrical shock, do not expose 

this product to rain or moisture.

Summary of Contents for QMR SERIES

Page 1: ...dome with two 2 Day Night cameras 3 9mm auto iris lens QMRT4 70NA Recessed tinted indoor outdoor ceiling dome with four 4 Day Night cameras 3 9mm auto iris lens Before attempting to connect or operate...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...oltage must be 24 VAC VDC Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten th...

Page 5: ...IVE For reference purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal...

Page 6: ...h is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the ca...

Page 7: ...onnecting the receiver end of the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 ca...

Page 8: ...t Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low vo...

Page 9: ...1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List...

Page 10: ...d bracket 5 RPQF20NF3 hi res b w 3 6 fixed lens RPQF20NA hi res b w 4 9mm auto iris varifocal RPQF50NF3 hi res color 3 6 fixed lens RPQF50NA hi res color 4 9mm auto iris varifocal RPQF70NA hi res day...

Page 11: ...en turning To adjust turn either clock wise or counter clockwise no more than one degree at a time Check the monitor after each turn to determine is the desired brightness and color have been obtained...

Page 12: ...polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both...

Page 13: ...RAS TOTAL LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2...

Page 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...

Reviews: