Use the formula below to select the correct power supply for cameras connected in parallel (positive to positive, negative to negative):

Total current for a 24 VAC system:
TOTAL CURRENT = (202mA x total number of cameras)   Example: 202mA x 5 total cameras = 1010mA
                                  Note: 202mA is camera plus power supply

CAMERAS     VOLTAGE          CURRENT         POWER
        1              24 VAC/VDC     102mA               2.5W
        2              24 VAC/VDC     210mA               5W
        3              24 VAC/VDC     331mA               7.9W
        4              24 VAC/VDC     487mA               10.9W

CABLE AND POWER GUIDELINES

This chart shows the proper current needed for power supplies for Q-View Series cameras. Use Class 2 Power only. Input voltage must be 24 VAC/VDC.

Power Supply Cable Maximum Length (feet/meters)

CAMERAS     TOTAL LOAD     POWER SUPPLy      24 AWG          22 AWG            18 AWG            16 AWG
        1                   2.5W               24 VAC/VDC           1718/523          2733/833         6909/2106       10985/3348
        2                   5W                  24 VAC/VC              834/254           1327/404         3356/1023         5335/1626
        3                   7.9W               24 VAC/VDC            529/161           842/256           2129/649           3385/1032
        4                   10.9W             24 VAC/VDC            359/109           572/174           1447/441           2300/701

NOTE:

 The above table is based on a "worst-case" power supply. Using a regulated or switching power supply can increase your cable 

            distance. Videolarm recommends using our PS24 power supply, or a CSA/UL listed Class 2 power supply.

Video Cable Maximum Length (feet/meters)

Cable Type           RG-59             RG-6             RG-11
Wire Gauge        23 AWG*       18 AWG*        16 AWG*
 Max. Length       750/229         1500/457       2000/610

* Copper clad steel core, 95% braided shield

AWG          250/76          500/152          1000/305          1500/457          2000/610          3000/914
  18                3Ω                 6Ω                  13Ω                   19Ω                  26Ω                 40Ω
  20                5Ω                10Ω                 20Ω                   30Ω                  40Ω                 59Ω
  22                8Ω                17Ω                 33Ω                   48Ω                  66Ω                 99Ω
  24              13Ω                26Ω                 52Ω                   78Ω                108Ω                163Ω          

Maximum Length (feet/meters)

Summary of Contents for QMR SERIES

Page 1: ...dome with two 2 Day Night cameras 3 9mm auto iris lens QMRT4 70NA Recessed tinted indoor outdoor ceiling dome with four 4 Day Night cameras 3 9mm auto iris lens Before attempting to connect or operate...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...oltage must be 24 VAC VDC Figure 1 Figure 2 7 With the bottom flange pressed up against the ceiling rotate the support arms to the outside the arms will fall to the back side of the ceiling Tighten th...

Page 5: ...IVE For reference purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground metal conduit metal...

Page 6: ...h is in the on position the auto iris lens controls the amount of light on the chip If in the off position the light level is controlled electronically Used to help improve the color quality of the ca...

Page 7: ...onnecting the receiver end of the unshielded twisted pair cable will be included with the NVT receiver Following are instructions for connecting the unshielded twisted pair cables to the RJ45 Cat 5 ca...

Page 8: ...t Unshielded Twisted Pair wire gauge 24 or thicker stranded or solid Category 2 3 4 or 5 2 The video signal may co exist in the same wire bundle as other video telephone data control signals or low vo...

Page 9: ...1 2 4 3 5 MR7 Exploded Diagram and Replacement Parts List...

Page 10: ...d bracket 5 RPQF20NF3 hi res b w 3 6 fixed lens RPQF20NA hi res b w 4 9mm auto iris varifocal RPQF50NF3 hi res color 3 6 fixed lens RPQF50NA hi res color 4 9mm auto iris varifocal RPQF70NA hi res day...

Page 11: ...en turning To adjust turn either clock wise or counter clockwise no more than one degree at a time Check the monitor after each turn to determine is the desired brightness and color have been obtained...

Page 12: ...polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both...

Page 13: ...RAS TOTAL LOAD POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2...

Page 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...

Reviews: