CAUTION 

1. The UVC filter should placed in somewhere that the water will not submerge it, and it should be 
2 meters distance from the edge of the pond to the filter. This equipment can not be used under 
the water. 
2. Before the water circulation, the electrical source of the UVC filer can not be switched on. 
3. Please place the UVC in the steady and safe spot. Because the UV light tube is made of quartz 
glass which is easy to be broken. 
4. Before all parts are installed completely, the electrical source can not switch on. 
5. If the UV light tube or the body shell looks like broken, the equipment can not be used. 
6. When any person in the water, the UVC can not be used. 
7. Please make sure that the electrical voltage, frequency used are consistent with the indication 
on the scutcheon of the UVC filter. 
8. When installing the equipment, the installation regulation of domestic should be followed. 
9. Pull the connecting cable is forbidden. And please protect the connecting cable from heat, 
greasiness or sharpness. 
10. Make sure the max pressure of the body shell ensured is less than 0.3 bar. 
11. When know the frost is coming, please move away UV filter. 
12. When install the UV filter, please not let it under the sunlight directly. 
13. The dirtiness on the quartz tube will influence the effect of the equipment, please clean the 
quartz tube in time. 
14. in order to ensure the effect of the equipment, the UV light tube should be replaced after 
8000 hours’ usage. 
15. When the body shell is blocked with the sands rubbish, it may destroy the quartz tube. 
So please add the filter sponge in the inlet of the water pump. 
16.UVC is harmful to the eyes and skin. Please do not watch UVC directly or let the skin approach 
to the UVC. 

INSTRUCTION 

1. The equipment can kill the harmful germ and algae in the aquarium and the pond which offer 
the healthy environment to the fishes. 
2. When the water under the irradiation f wavelength in 253.7nm’s ultraviolet radiation in a short 
period, the germ and pathogen in the water will be killed then. 
3. This equipment is not sell with the pump, please buy it yourself. 
4. Please connect the inlet pipe with the other filter or the pond. 
5. Please connect the outlet pipe with the other filter or the pond and fix it. After the inspection of 
the pipe and the connecting part, the water circulation can be started then. 
6. Plese check it when the water started circulation or not after several minutes. 
7. Turning on the electrical source, the UV filter begin to work. 
8. The detailed sketch map pf usage can be pound in the packing box. 
9. CUV-218/224/236 series are equipped with flow adjuster, which should be installed to the 
outlet. Please install the flow adjuster to the neatest outlet, and closed all, if the flow of pump 
is less than 2000L/H,CUV-218;2500L/H,CUV-224;3000L/H,CUV-236 If the flow is larger than 
above, please adjust according to the actual conditions. Ensure the flow through the effective 

Summary of Contents for 105821

Page 1: ...www DEUBAXXL de DE EN FR UV C Wasserkl rer Artikel Nr 105821 Modell Nr DBWC001...

Page 2: ...Beachten Sie die Sicherheitshinweise und Aufbauanweisungen um das Risiko von Verletzungen oder Besch digungen am Produkt zu vermeiden ERSTICKUNGSGEFAHR Halten Sie kleine Teile und Verpackungsmaterial...

Page 3: ...bei Frost 12 Installieren Sie den UV Filter nicht in direktem Sonnenlicht 13 Schmutz im Quarzrohr beeintr chtigt die Leistung des Filters Reinigen Sie das Lichtrohr rechtzeitig und regelm ig 14 Ersetz...

Page 4: ...36 CUV 207 209 211 bitte Sicherheitsknopf dr cken D Nun k nnen Sie die UV Lampe von CUV 207 209 211 ersetzen und das Quarzglas von CUV 218 224 236 reinigen E CUV 218 224 236 L sen Sie die Mutter am Qu...

Page 5: ...ausm ll entsorgt werden darf Altger te enthalten wertvolle recyclingf hige Materialien die einer Wiederverwertung zugef hrt werden sollten und um die Umwelt bzw der menschlichen Gesundheit nicht durch...

Page 6: ...he future please ensure you also pass on this manual Keep small parts plastic bags and other packaging out of the reach of children Pay attention especially when unpacking your item Danger of suffocat...

Page 7: ...der to ensure the effect of the equipment the UV light tube should be replaced after 8000 hours usage 15 When the body shell is blocked with the sands rubbish it may destroy the quartz tube So please...

Page 8: ...use a dry cloth to hold the tube I When replacing the new tube please remove the fixed nip and make it bad then change for a new one also J Please make sure all seal parts are clean and all into corr...

Page 9: ...T Gardez les petites pi ces et le mat riel d emballage hors de port e des enfants V rifiez l int gralit et le bon tat du produit sa r ception Toute r clamation ult rieure pour produit incomplet ou end...

Page 10: ...t tre remplac e apr s 8000 heures d utilisation 15 Lorsque la coque du corps est bloqu e avec les d chets d truire le tube de quartz Veuillez donc ajouter le filtre ponge l entr e de la pompe eau 16 L...

Page 11: ...euillez retirez le pincement fixe c est galement mauvais le changement pour un nouveau J Veuillez vous assurer que toutes les pi ces du joint sont propres et dans la bonne position en particulier le j...

Page 12: ...12 www DEUBAXXL de...

Page 13: ...IT Per qualsiasi tipo di servizio reclami e supporto tecnico puoi rivolgerti con fiducia al nostro personale qualificato Hergestellt f r Deuba GmbH Co KG Zum Wiesenhof 84 66663 Merzig Germany Copyrig...

Reviews: