ASSEMBLY
WIRING DIAGRAMS FOR CONNECTING THE UNIT TO DIFFERENT PUMP MOTORS
STARTING
• When the unit is connected to the electrical network, the green LED „Strom AN“ lights up and the
the required pressure.
• If this process is
cient, the red LED „Störung“ lights up. In this event, keep the „Neustart“
FUNCTIONING
signal is sent to the pump to prevent damage caused by its working in the absence of water.
MAINTENANCE
The device does not require any special maintenance.
Repairs may only be done b
rson.
W
of single phase 230V pumps up
to 1.1 kW.
W
of single phase 230V pumps
over 1.1 kW through remote
control switch.
W
of three phase 380V motor
pumps through remote control
switch.
SPECIFICATIONS FOR REMOTE
CONTROL SWITCH
Minimum contacts capacity of
4 kW or 5.5 HP approx. 230V
SPECIFICATIONS FOR REMOTE
CONTROL SWITCH
Minimum contacts capacity of
4 kW or 5.5 HP approx. 230V
Type of defect
Causes depending on the unit
Causes not depending on the unit
• The pump does not
start.
• The circuit board is broken.
• Missing voltage
• Pump jammed
• Electric cables inverted
(Line/Motor)
• The pump does not
stop.
• The circuit board is broken.
• The ow detector is tapped in
the upper position.
• The restart button (Neustart) is
blocked.
• The pump does not provide
suf cient pressure.
• Loss of more than 0.6 l/min due to
a leak
• Pump works
intermittently.
• The circuit board is broken.
• The pump does not provide
suf cient pressure.
• Loss of less than 0.6 l /min due to
a leak
• The pump is blocked.
• The circuit board is broken.
• The pump provides a pressure
which is lower than the restarting
pressure.
• Missing water
• Suction problems
TROUBLESHOOTING