W3400 Gas Fireplace

WARNING:

If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.

If you cannot reach your gas supplier, call the Fire
Department.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If  the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.

A.

This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING

 smell all around the appliance area for

gas.  Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

What To Do If You Smell Gas:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any
phone in your building.

Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

Operation - Model W3400

3. Push in gas control knob slightly and turn  

  clockwise

to "Off".  Do not force.

4. Flip up lower brass trim.

1. Turn off remote switch.

2. Flip down lower brass trim.

1. STOP!

 

 

Read the safety information above on this label.

2.

Flip down lower brass trims.

3.

Push in gas control knob and turn clockwise 

  to

"OFF."

4.

Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, 

STOP!

Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.

5.

Locate pilot burner 

(See illustration at right.)

 and follow

steps below.

6.

Turn knob on gas control counterclockwise  

  to

"PILOT."

7.

Push in gas control knob completely and hold. Light with
Piezo Igniter button. Continue to hold the control knob in for
about (1) minute after the pilot is lit. Release the knob and it
will pop back up. Pilot should remain lit. If it goes out repeat
steps 3 through 8.

If knob does not pop up when released. Stop and
immediately call your service technician or gas supplier.

If the pilot will not stay lit
after several tries, turn the
gas control knob to "OFF"
and call your service
technician or gas supplier.

8.

Push in gas control knob and
turn counterclockwise  

  to "ON."

9.

Flip up lower brass trim.

10.

Turn on remote switch to ignite fire.

Lighting Instructions:

W3400

with Continuous  Pilot

For Your Safety - READ BEFORE LIGHTING:

Gas Control Knob
(Shown in "Pilot" postion.)

NOTE:

Knob cannot be turned from
"PILOT" to "OFF" unless knob is
pushed in slightly.  Do not force.

Summary of Contents for Wildfire MW34-DV

Page 1: ... Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For ...

Page 2: ...Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations If the optional air circulating fan kit is installed it must be electrically grounded in accordance with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must conform to local codes or in the absense of local codes to the National Fuel Gas Code ...

Page 3: ...directly on carpeting tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extending the full width and depth of the appliance Rear Vent Clearances The W3400clearances to combustible materials are Top Rear Vent 7 Top Top Vent 13 Back 0 Side 1 Floor 0 Mantle 10 Clearancefromthetopofthefireplacetoacombustible ceilingwithinthefireplaceenclosure Refer...

Page 4: ...ately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable brass trim at the bottom of the unit and need only be attached to the gas line with an approved fitting as required by the applicable installation codes Installation Figure 6 Fireplace locations and vent terminations Note After gas line is connect...

Page 5: ...s high rises where the termination may not be easily installed from the building s exterior 1 Frame the termination opening to 12 x 12 2 Fasten the MOSR frame to the interior side of the studs using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here and attach by screwing through the four pilot holes in the termination 12 12 12 MOSR Installing Terminations with MSR or...

Page 6: ...the vertical dimension from the floor of the fireplace is 78 and the horizontal run to the wall flange of the vent termination is 108 this would NOT be an acceptable installation Top Vent 0 12 24 36 48 60 72 84 96 108 132 120 144 156 168 180 Horizontal Run in Hearth 0 12 24 36 48 60 72 84 96 108 Heat Shields Due to high flue temperatures heat shields are required on all 34 Series Modular Direct Ve...

Page 7: ...ure 9a Typical Top Vent installation If the 90 elbow is installed directly on the fireplace the height to the center of the termination is 44 Horizontal Venting Figure 9b Typical Top Vent installation The solid sections can be used in various combinations to obtain the desired vent run The vent run must fall within the limits set by the venting graph 90 Elbow MEXT Section Heat Shield Example 2 A 1...

Page 8: ... maintained Figure 13 Straight vertical venting using required PXT 10 adaptor Amaximumoftwooffsetswith90 bendsmaybemadeandshallnot exceedtotallengthof25 oftheverticalventheight whenmeasured center to center of piping Example Typical vent installation 20 vertical vent 2 2 offsets required 25 of 20 5 max offset allowed This venting configuration meets requirements A Termination PVTK 1 B Flex section...

Page 9: ...ons theW3400Rmaybeinstalled with 2 90 elbows and up to 15 of horizontal run If using this installationoption youmustadheretothefollowingguidelines the first 90 elbow must be placed directly on the flue collar you must have a minimum vertical lift of 50 measured from the hearth your vent run must fall within the limits set by Figure 19 Before you install any venting you must determine whether the v...

Page 10: ... frame BSR 4 4 brick frame BSR 6 6 brick frame MOSR stucco can D Flex sections PFL 1 12 section PFL 2 24 section PFL 3 36 section PFL 4 48 section E Solid sections PEXT 1 12 section PEXT 2 24 section PEXT 3 36 section PEXT 4 48 section F 90 degree elbow MEL 90 90 elbow NOTES All dimension lengths for vertical or horizontal runs are measured from center of the vent pipe Venting runs must fall withi...

Page 11: ... over coats Top of fireplace Combustible Facing Combustible construction allowed in shaded area 1 2 3 4 5 6 7 8 9 10 11 12 Figure 19a Combustible mantles and facings Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted u...

Page 12: ...Gas Control SV9501M Gas Control Connector Fuse Limit Switch Wall Switch Fan Plug Receptacle Junction Box Junction Box Cover White Black Green 40 VA Transformer 115VAC 24VAC Grnd Screw Figure 20 Wiring for the W3410 with Honeywell gas control and pilot Wiring for the optional Fan and Blower Kits This fireplace may be equipped with an optional fan pack or blower for circulatingheatintothelivingspace...

Page 13: ... pull the bottom outwards and lift upwards until the slots A are clear of tabs B in the door You may need to use a flat screwdriver to pull the door surround outwards See figure 23a Machine Screws Door Rail Tabs Glass door frame Removing the door To install remove the glass door simply attach remove the ten 10 machine screws that hold door in place See figure 23b Ensure that a good seal is maintai...

Page 14: ...00 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower brass trim 1 Turn off remote switch 2 Flip down lower brass trim 1 STOP Read the safety information above on this label 2 Flip down lower brass trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas...

Page 15: ...ppliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower brass trim 3 Turn the switch on the gas control to Off 4 Flip up brass trim 1 STOP Read the safety information above on this label 2 Flip down lower brass trims 3 Turn switch o...

Page 16: ...nob marked Hi Lo in the centre of the gas control valve See Figure 27 To raise the flame height turn the black knob located behind the lower trim counterclockwise To lower the flame height turn clockwise Gas Control Knob Shown in Pilot postion Hi Lo Adjustment Knob Figure 24 Hi Lo Adjustment on Model W3400 gas valve Cleaning When the fireplace is first activated there may be some smoking and a vis...

Page 17: ... SV9500 SV9600 Check Transformer Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transformer Limit Controller Thermostat Wiring Air proving switch on combustion air blower system Vent damper if used is open and end switch made Gas Control Valve Figure 25 Sit Nova 820 gas valve Pilot Burner Adjustment 1 ...

Page 18: ...fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other warranty expressed o...

Page 19: ...uard MTKOG 7 Wildfire 4 piece Logset 8 4 Piece Picture Frame Surround PFS 9 3 Piece Picture Frame Surround PFO 10 Horizontal Trim Kits 11 Door Cover Square DF0 12 Door Cover Arched DFA 13 ControlModuleforModelW3400 14 ControlModuleforModelW3400 I 15 Aluminum Tubing 1 4 dia 16 Locking Nuts 17 Spacer 18 Bulkhead Fitting 19 90 Elbow 20 Burner Orifice 21 Burner Tube 13 10 11 14 17 18 19 21 16 15 20 7 ...

Page 20: ...Page 20 of 21 W3400 Gas Fireplace Appendix B Termination Locations 16 ...

Page 21: ...Page 21 of 21 W3400 Gas Fireplace Notes ...

Page 22: ...Page 22 of 21 W3400 Gas Fireplace Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0107 Rev 02 04 99 ...

Reviews: