Step 6
: Pull Power Vent connector from behind half way through supplied
hole in conduit mounting frame. Snap into place, notches in two plastic
wing clip. See
Figure 13d.
Power Vent Harness
Strain Relief & tightened nut
Power Vent
Connector
Conduit
mounting
frame
Tightened hardware, 4-pcs.
Figure 13d.
Installing conduit connector and conduit mounting frame.
Step 7
: Fasten conduit mounting frame into place using existing
hardware, six pieces. Coil conduit behind cover. See
Figure 13e.
Tightened hardware, 6-pcs.
Installed Power Vent
Connector
Figure 11e.
Assembled Rough-in Kit.
Step 8
: Install the Power Vent power harness. Hold the Power Vent in
close proximity to the assembled Rough-in Kit. Plug in the Power Vent
harness. See
Figure 13f.
TOP of Power Vent
Note louver
direction
Power Vent
Harness.
Figure 13f.
Installation of Power vent harness.
Tightened hardware,
4-pcs.
Figure 13g.
Completed Power Vent installation.
Step 4
: Insert the conduit from the Power Vent module into the rough-in frame
through the two top right entry holes. Remove the nut from the supplied strain
relief and place as show in
Figure 13c.
Power Vent Harness
Strain Relief
Nut
Strain Relief
Figure 13c.
Installing Power Vent Conduit.
Step 5
: Securely fasten bottom collar pan into rough-in frame using the
existing hardware, 4-pieces. Tighten strain relief nut onto strain relief.
Step 9
: Install the Power Vent. Place the Power Vent into the rough-in
frame, aligning the Power Vent into final position. Ensure the power
harness is placed down in the rough-in frame when placing the Power
Vent. Secure the Power Vent in place with the supplied hardware, 4
pieces. See
Figure 13f.
R520 & R620 Power Vent Indoor Gas Fireplace
Page 22
XG0771 - 040513.3
Installation