Step 12:
Using the ground screw, screw the capacitor bracket and
the ground wire to the motor.
Step 13:
Strip the ends of all the wires. Using the large bell connec-
tor, connect the white fibre wire from the power cable to the black wire
from the motor and one of the black wires from the capacitor.
Figure 6m.
Step 14:
Using a small bell connector, connect the black fibre wire
from the power cable to the blue wire of the motor.
Figure 6n.
Step 15:
Using the other small bell connector, connect the other
black wire from the capacitor to the brown wire from the motor.
Figure 6o.
Step 16:
Using a zap strap to bundle the wires neatly together.
Figure 6p.
Step 17:
Using another zap strap, secure the bundle to the capacitor.
Figure 6q.