XT0016
3
Installation
RX 200
Control Module Disconnect
RX 200
Stepper Motor Installation
A. Disconnect Control Module and Harness:
1. Disconnect Control Module Powercord from the PPO box.
B. Stepper Motor Installation
1. Using a Torx T20 or slotted screw driver, remove the two screws that
are attached to the Hi-Low knob on the Gas Control Valve (Figure 7)
and discard the screws and the knob. Remove gasket and discard.
2. Disconnect Spark Wire and Sensor Wire from connectors X2 and X3
of the control module.
3. Disconnect the wall switch harness from X4 Control Module and
discard.
4. Remove the Valve Harness from X5 of the control module.
5. Remove the connector from X1 of the control module.
6. Remove the control module from firebox compartment and discard.
Note: module is attached by velcro strips.
Figure 3
Powercord in PPO box
Figure 4
Control module with wires
Figure 5
X5 plug of control module
Figure 6
X1 plug of control module
Figure 7
Replace Hi-Lo knob on valve
Figure 8
Discard spring
and gasket
Discard knob
and screws
Figure 9
Stepper Motor - LP
Figure 10
Stepper Motor - NG