Montigo LDVPV47 Installation & Maintenance Manual Download Page 3

Page 3

You  must  read  and  understand  this  manual  prior  to  installation,  operation  or 

troubleshooting this appliance. Please retain this owner’s manual for furure reference 

and maintenance.

NOTICE

LDVPV47 Linear Power Vent System

Introduction

XG0750 - 112911

General Information

This installation guide covers installation of the Linear Power Vent System 

only. This system is designed to allow installation of gas fireplaces that 

cannot be done with a standard Direct Vent gas fireplace installation.
Specifications and instructions pertaining to your chosen fireplace must 

be followed.  Please read this Installation Operation and Maintenance 

Instructions carefully before operating this equipment.
 

 

Standard Series (4"/7" dia.) Termination System:

 

LDVPV47 - Linear Power Vent System

 

Pre/Post Purge Control Box

 

RHSIT05 -Control module, provides pre/post purge. (HSI System)

        ECB-007 Post Purge control box (IPI System) 

 

Power Cord Harnesses:

 

LPVH10 -10 foot power cord and harness

 

LPVH20 -20 foot power cord and harness

 

LPVH30 -30 foot power cord and harness

 

LPVH40 -40 foot power cord and harness

 

LPVH50 -50 foot power cord and harness

 

LPVH60 -60 foot power cord and harness

 

LPVH70 -70 foot power cord and harness

 

LPVH80 -80 foot power cord and harness

Selecting and Installing the Fireplace

The Linear Power Vent System must only be used with a Montigo Direct 

Vent Fireplace. When selecting a gas fireplace for use with the Linear 

Power Vent System, take into consideration the various requirements and 

limitations in the 

venting installation section

 of the Model's manual: 

Models Must Be Equipped with Electronic Ignition 

(HSI/IPI)

Only  models  equipped  with  an  electronic  ignition  system  may  be 

installed with the Linear Power Vent System.  This system allows for 

greater  flexibility  on  venting  requirements.  For  example    downward 

vertical vent runs are possible with an HSI/IPI system, as outlined in 

the 

Venting Section.

All fireplaces with 5"/8" venting must be reduced to 4"/7" venting  

in order to be used with the Linear Power Vent System.

Before You Begin

 

„

Minimum clearances of 1" from vent to all combustible materials 

must be maintained. 

 

„

The  LDVPV  must  only    be  installed  with  Montigo  venting 

components.  The  LDVPV may be used with any of the available 

Montigo terminations.

 

„

In order to maintain the power vent system integrity all 4" 

and 7" venting connections must be fastened with three 

self tapping screws.

 

„

Installation of the LDVPV must comply with this manual, and be 

completed by a qualified professional.

 

„

Plan the layout of the installation's venting run before starting 

the installation.

 

„

The MAXIMUM total allowable length; Refer to Linear Power 

Vent Installation Section, Page 4-6.

 

„

Downward venting is allowable.  Please refer to Page 5 for a 

table and illustrations regarding the limitations of this type of 

installation.

 

„

Minimum length of straight pipe between the Fireplace and the 

Power Vent is:  2 feet

 

„

Access / Service Panel, must maintain 1" clearance. Minimum 

30% free air must be supplied to the motor. 

 

„

Disconnect  the  power  supply  when  installing  and/or 

servicing the fireplace or the power vent system.

When cold air enters warm building interiors, primarily at the air intake end, 

condensation may occur on the exterior of the flex pipe. To limit condensation, install

insulation over the last 20 feet of flex pipe. Sloping the last 20 - 0 feet of flex pipe 

downward to the exterior of the building may also aid in eliminating condensation. 

 Ensure the termination is securly fastened and is sealed to the flex pipe. Fasten the 

termination to building exterior with water tight sealant and appropriate fasteners.

CAUTIO N

Ensure perforated air holes in the new pipe adapter / restrictor are not covered

when installing new pipe connection. 

CAUTION

Due to high operating temperatures, this appliance should  be located out of traffic & 

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature, 

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the 

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION

Summary of Contents for LDVPV47

Page 1: ...field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger...

Page 2: ...ER WARNING CAUTION NOTICE Safety Alert Key LDVPV47 Linear Power Vent System XG00750 112911 Safety Alert Key 2 Introduction 3 Before you Start 3 Section 1 Installation 4 9 Unit Dimensions 4 Installatio...

Page 3: ...the Linear Power Vent System Before You Begin Minimum clearances of 1 from vent to all combustible materials must be maintained The LDVPV must only be installed with Montigo venting components The LD...

Page 4: ...age 4 LDVPV47 Linear Power Vent System XG0750 112911 Installation 27 15 16 16 5 16 10 1 16 2 6 7 4 1 0 14 7 16 2 7 16 1 5 16 33 3 4 16 7 16 1 0 FAN SHIELD Figure 1 LDVPV47 Linear Power Vent dimensions...

Page 5: ...ction in the fireplace s Installation Operation and Maintenance Instructions as well as the following guidelines Ensure that the planned termination location is acceptable as shown in Appendix A Minim...

Page 6: ...Igniter Electronic Ignition Gas Control Exterior Wall LDVPV47 110V power supply 2Amp MAX Wall Switch 110V power supply 4Amp MAX Optional Stainless Steel louvered Termination kit Power Cord 10 Long Par...

Page 7: ...l Example B Horizontal Mounting with horizontal Vent Run Horizontal Installed Linear Power Vent Horizontal Run Flex Pipe Vertical Flex Pipe 90deg Elbow 90deg Elbow 90deg Elbow Termination Snorkel Term...

Page 8: ...rances to combustibles The required service access panel must be framed at 18 X 18 To enclose the service access panel at less than 1 a minimum 30 free air must be supplied at all times 2 Plugthepower...

Page 9: ...wer Vent for specific Model Fireplaces L52 DF and L52 DF ST Gas fireplace models Figure 8 L52 DF and L52 DF ST vent clearances 4 0 MIN Power Vent 1 MIN 4 0 Clearance void must be maintained at both en...

Page 10: ...tion Upper Casing of Fireplace Strain Relief Wall Switch Limit Switch Air Proving Switch Fuse G L2 L1 Bk Bl Bl Bk Bk Bk Bk TDR TDR Coil R R R W W W W W Transformer Strain Relief 115V 24V Gas Control C...

Page 11: ...ls LVA5487 H52CA03 Installed with LDVPV58 on the Following models LVA47 4 5 Dilution holes 2 1 250 Exhaust hole 3 4 5 Dilution holes 2 1 250 Exhaust hole 2 375 M40 Series L38DFN L42DFN H38DFN HL38DFN...

Page 12: ...um in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for applian...

Page 13: ...ompanies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel wil...

Page 14: ...ght of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one...

Page 15: ...Page 15 L42DF Indoor Gas Fireplace XG0181 053111 Notes Notes...

Page 16: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0750 112911 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 LDVPV47 Linear Power Vent System...

Reviews: