Appendix B: Warranty

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, 

there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control 

valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 

Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of 

local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, 

specifications, prices and also to discontinue colors, styles and products.

Summary of Contents for LDVPV47

Page 1: ...field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger...

Page 2: ...ER WARNING CAUTION NOTICE Safety Alert Key LDVPV47 Linear Power Vent System XG00750 112911 Safety Alert Key 2 Introduction 3 Before you Start 3 Section 1 Installation 4 9 Unit Dimensions 4 Installatio...

Page 3: ...the Linear Power Vent System Before You Begin Minimum clearances of 1 from vent to all combustible materials must be maintained The LDVPV must only be installed with Montigo venting components The LD...

Page 4: ...age 4 LDVPV47 Linear Power Vent System XG0750 112911 Installation 27 15 16 16 5 16 10 1 16 2 6 7 4 1 0 14 7 16 2 7 16 1 5 16 33 3 4 16 7 16 1 0 FAN SHIELD Figure 1 LDVPV47 Linear Power Vent dimensions...

Page 5: ...ction in the fireplace s Installation Operation and Maintenance Instructions as well as the following guidelines Ensure that the planned termination location is acceptable as shown in Appendix A Minim...

Page 6: ...Igniter Electronic Ignition Gas Control Exterior Wall LDVPV47 110V power supply 2Amp MAX Wall Switch 110V power supply 4Amp MAX Optional Stainless Steel louvered Termination kit Power Cord 10 Long Par...

Page 7: ...l Example B Horizontal Mounting with horizontal Vent Run Horizontal Installed Linear Power Vent Horizontal Run Flex Pipe Vertical Flex Pipe 90deg Elbow 90deg Elbow 90deg Elbow Termination Snorkel Term...

Page 8: ...rances to combustibles The required service access panel must be framed at 18 X 18 To enclose the service access panel at less than 1 a minimum 30 free air must be supplied at all times 2 Plugthepower...

Page 9: ...wer Vent for specific Model Fireplaces L52 DF and L52 DF ST Gas fireplace models Figure 8 L52 DF and L52 DF ST vent clearances 4 0 MIN Power Vent 1 MIN 4 0 Clearance void must be maintained at both en...

Page 10: ...tion Upper Casing of Fireplace Strain Relief Wall Switch Limit Switch Air Proving Switch Fuse G L2 L1 Bk Bl Bl Bk Bk Bk Bk TDR TDR Coil R R R W W W W W Transformer Strain Relief 115V 24V Gas Control C...

Page 11: ...ls LVA5487 H52CA03 Installed with LDVPV58 on the Following models LVA47 4 5 Dilution holes 2 1 250 Exhaust hole 3 4 5 Dilution holes 2 1 250 Exhaust hole 2 375 M40 Series L38DFN L42DFN H38DFN HL38DFN...

Page 12: ...um in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for applian...

Page 13: ...ompanies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel wil...

Page 14: ...ght of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one...

Page 15: ...Page 15 L42DF Indoor Gas Fireplace XG0181 053111 Notes Notes...

Page 16: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0750 112911 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 LDVPV47 Linear Power Vent System...

Reviews: