L38DF-ST* Indoor Gas Fireplace
Page 24
XG0810 - 151126
Installation
Section 8: Installing & Removing the Door
Removing the door:
The L38DF-ST* doors are removed in a few simple steps. Follow
these instructions below to remove the Horizontal access panel,
unlatch the door buckles and, remove the door. Replace in
reverse order.
Figure 23a. Locate the door buckles. Both sides typical.
Figure 23. Removing and installing the Horizontal Access Panel
Locate the Door Buckles.
Step 2:
Step 1:
Remove the Horizontal cover
by placing fingers in both
finger holes, then pushing
away from you and lifting
out. Place it aside during
maintenance or cleaning.
Install in reverse order.
2
Step 5:
Ensure the tool is
firmly in the lower end
of the slot, (as shown),
Then pull toward you
(Caution: hold the tool
securely).
3
Step 6:
Pull hard if necessary to
release the spring ten-
sion. (Caution: The latch
springs back with force,
hold the tool securely).
4
Step 7:
Remove the tool from
the latch slot. Ensure
the latches are hanging
freely, the hook end is
released from the bottom
of the door. (Repeat all
4-steps for the remaining
latches).
Figure 23d.
Figure 23e.
Figure 23f.
Door Latch Hook
Door Latch Slot
Hand-hold
Figure 23b. Door buckle Tool
1
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under
door frame. (as shown)
Figure 23c.
Finger Holes
Installed Gas
Valve Cover
Step 3:
Locate Door Buckle Tool.
WARNING
When reinstalling door(s), always make sure all door