L38DF-ST* Indoor Gas Fireplace
Page 15
XG0810 - 151126
Installation
42”
42”
26 3/4”
12”
Figure 13b.
Side Vented, wall mounted Multi-elbow termination
installation. Installation for L38DF*-ST must have a
minimum vertical rise of 42".The vent run must comply
with the Venting Graph for Rear vent, wall mounted
terminations, Figure 13.
Figure 13a. Straight run, Side Vented, wall mounted termination
for L38DF-ST*, Figure 13.
Notes Wall Mounted Terminations: SIDE VENT
All dimension lengths for vertical or horizontal runs are
measured from center of the vent pipe.
Venting runs must fall within the limits set by the venting
graphs, see Figure 13.
Fireplace must be converted to Rear Vent configuration
prior to running vent, see Figure 8 and 8a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre
of the termination and the horizontal run from the fireplace flue
collar to the wall flange of the termination. Plot on the Venting
Graph Figure 13 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the
horizontal run to the wall flange of the vent termination is
138", this would be an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal
run to the wall flange of the vent termination is 96", this would
be would NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72"
and the horizontal run to the wall flange of the vent termination
is 120", this would NOT be an acceptable installation.
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
30” Max.
42” Min.
12”
Max.
Flex or Rigid
Section
15 1/4”
Min.
26 3/4”
Hearth
26 3/4”
PXT Extension
RHS101 Heat
Shield
Termination
Hearth
Exterior
Wall
NOTE:
12” MAX. horizontal
run with no vertical lift.
12” MAX.
If your installation does not fall within
the venting parameters, contact a
local Montigo dealer for Power
Venting options.
A
C
B
Figure 13. Side Vent Venting Graph for wall mounted termina-
tions.
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.